Hybrid Battery Refrigerant Shut-Off Valve 1 -N516-, REMOVING AND INSTALLING: Removing
WARNING: This page does not describe the selected car, but rather 13 other vehicles, including the 2017 Audi SQ5, 2017 Audi Q5, 2016 Audi SQ5, 2016 Audi Q5, and 2015 Audi SQ5. However, it is still accessible from the selected car via links, so may be relevant.
-- Turn off the ignition.
-- Discharge the refrigerant circuit. Refer to USING SERVICE STATION (Refrigerant R134a, Servicing; Refrigerant Circuit, Using Service Station).
-- Free up the clip -2- for the wiring harness on the refrigerant pipe.
-- Remove the bolt -3- and separate the refrigerant pipe -4-.
NOTE:
Ignore items -1, 5 and 6-.
-- Disconnect and remove the connector -3- from the bracket.
-- Remove the union nuts -1 and 2- while counterholding on the connection and remove the Hybrid Battery Refrigerant Shut-Off Valve 1 -N516-.