LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 603 (Battery & Generator) >> 27 Starter, Generator And Cruise Control >> Battery, Charging >> Battery Charger VAS5900 >> Battery Charger VAS5900 MAINTENANCE CHARGING

Battery Charger VAS5900 MAINTENANCE CHARGING

WARNING: This page does not describe the selected car, but rather 13 other vehicles, including the 2017 Audi SQ5, 2017 Audi Q5, 2016 Audi SQ5, 2016 Audi Q5, and 2015 Audi SQ5. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:

If the Battery -A- is discharged by an electrical consumer during maintenance charging, the Battery Charger VAS5900 automatically supplies the appropriate charge.

Maintenance charging can be performed without time restrictions.

The Battery -A- can be used constantly.

Observe the maintenance notes of the battery manufacturer.

WARNING:

Risk of injury. Follow all warning messages and safety precautions. Refer to WARNINGS AND SAFETY PRECAUTIONS .

WARNING:

Do not check or charge a Battery -A- when the visual indicator has >>no color or is bright yellow<<. Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These Batteries -A- must be replaced.

If the Battery -A- is fully charged, the Battery Charger VAS5900 starts maintenance charging.

Special tools and workshop equipment required 

Procedure 

-- Proceed as if charging the Battery -A-. Refer to BATTERY, CHARGING WITH Battery Charger VAS5900 .

With a charge status of 100%, all bars are indicated on the display -1-.

Fig 1: Charging Unit Display, Charge Condition 100 %
GWWN27-10180Courtesy of AUDI OF AMERICA, LLC