LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 601 (Refrigerant R134A Servicing (1 Of 2)) >> 87 Air Conditioning >> Refrigerant Circuit >> Refrigerant Circuit, Determining Leaks >> Leak Detection On Refrigerant Circuit Using Leak Detection System Vas6201 >> Add UV-leak detection additive using the Leak Detection Kit VAS6201 in the refrigerant circuit

Add UV-leak detection additive using the Leak Detection Kit VAS6201 in the refrigerant circuit

WARNING: This page does not describe the selected car, but rather 13 other vehicles, including the 2017 Audi SQ5, 2017 Audi Q5, 2016 Audi SQ5, 2016 Audi Q5, and 2015 Audi SQ5. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

The leak detection system VAS6201 includes the following tools. (Refer to Tools; Special Tools and Equipment: A/C and Heating).

Fig 1: Identifying Leak Detection System VAS 6201
GWWA87-0494Courtesy of AUDI OF AMERICA, LLC
  1. Leak Detection Kit - Hand Pump w/Cartridge VAS6201/1
  2. Leak Detection Kit - Cartridge VAS6201/2 (with UV-leak detection additive)
  3. Leak Detection Kit - Cleaning Solution VAS6201/3
  4. UV Leak Detection Lamp VAS6201/4A
  5. Leak Detection Kit - Eye Protection VAS6201/6
  6. Leak Detection Kit - Label VAS6201/7
  7. Tube VAS6201/8
  8. Leak Detection Kit - Hand Protection VAS6201/9
NOTE:

Described in the following are instructions for how to pour the UV-leak detection additive into the refrigerant circuit using the Leak Detection Kit - VAS6201A-. If the UV-leak detection additive is added to the refrigerant circuit with the help of other tools (for example, with the A/C service station) read the applicable operating instructions.

The following is the given amount of UV-leak detection additive that is to be added to a refrigerant circuit with a refrigerant oil quantity of 100 to 150cm 3 using the Leak Detection Kit - VAS6201A- (2.5 ± 0.5 cm3 ). If the refrigerant oil capacity in the refrigerant circuit is larger, then more UV leak detection additive must be added accordingly (for example, 5.0 ± 0.5 cm3 for a refrigerant circuit with a refrigerant oil capacity of 250 cm 3 . For the relevant refrigerant oil quantities in the refrigerant circuit. Refer to APPROVED REFRIGERANT OILS AND CAPACITIES .

If the UV-leak detection additive is added to the refrigerant circuit with the help of other tools (for example, with the A/C service station), observe the prescribed quantities of UV-leak detection additive given in the corresponding operating instructions.