Electrically Driven A/C Compressor, Rinsing (Remove Refrigerant Oil)
Vehicles with a High Voltage System (Hybrid Vehicles)
Read and follow all of the supplemental warnings for all work performed on vehicles with the high voltage system. Refer to WARNINGS WHEN WORKING ON VEHICLES WITH HIGH VOLTAGE SYSTEM and HIGH VOLTAGE SYSTEM GENERAL WARNINGS .
Risk of unintended engine start
The ignition must be turned off and the ignition key must remain outside of the vehicle when working on vehicles with a high voltage system.
Handling high voltage cables:
- Do not stand on or place tools on high voltage cables and their components as it may damage the cable insulation.
- Never bend or kink high voltage cables forcefully as it may damage the cable insulation.
- The round high voltage connectors are color coded with an external color ring and are mechanically coded using the guide- or code tabs. Always make certain that the coding matches when connecting the round connector in order to avoid any mechanical damage the high voltage connector.
There is a risk of electrocution from damaged high voltage components.
Observe the following when working around high voltage components and high voltage wires:
- Never work around high voltage components and cables with cutting, deformed, or sharp edged tools, or heat sources such as welding or soldering tools, heated air, and thermal glue.
- Inspect the high voltage components visually before beginning.
- Perform a visual inspection of the Electric Drive Power and Control Electronics -JX1-, the Electro-Drive Drive Motor -V141-, the Electrical A/C Compressor -V470- and the high voltage lines when working in the engine compartment.
- Perform a visual inspection of the high voltage lines and covers when working on the underbody.
- Perform a visual inspection of the high voltage lines and the Electrobox with the High Voltage System Maintenance Connector -TW- when working in the luggage compartment.
- Perform a visual inspection on all of the potential equalization cables.
Observe the following items when performing the visual inspection:
- The components do not display any signs of external damage.
- The high voltage cable insulation and the potential equalization cables are not damaged.
- The high voltage cables do not display any abnormal deformations.
- Every high voltage component is marked with a red warning label.
If it is necessary to perform work in the vicinity of high voltage components, perform a "visual inspection" of the high voltage components and cables for damages (refer to PERFORMING A VISUAL INSPECTION OF DAMAGE TO HIGH VOLTAGE COMPONENTS AND CABLES ) and follow the "WARNINGS WHEN WORKING ON VEHICLES WITH HIGH VOLTAGE SYSTEM ". Refer to HIGH VOLTAGE SYSTEM GENERAL WARNINGS .
If it is necessary to perform work on the high voltage components, disable the high voltage system. Refer to HIGH VOLTAGE SYSTEM, DE-ENERGIZING and read and follow the "high voltage electrical system general warnings", refer to HIGH VOLTAGE SYSTEM GENERAL WARNINGS and WORKING ON HIGH VOLTAGE VEHICLES .
Disable the high voltage system
Risk of electrocution
Death or serious bodily injury by electric shock.
- The high voltage system may only be activated by qualified personnel (Audi high voltage mechanic).
- Make sure that the high voltage system is completely disabled. Make sure the vehicle is de-energized using "Guided Fault Finding " on the Vehicle Diagnostic Tester.
- The qualified personal (Audi high voltage technician) determines the voltage and secures the system from restarting using the Service Disconnect Lock T40262. Keep the ignition key and the High Voltage System Maintenance Connector -TW- safely with the qualified personal to secure the system from restarting.
- The Audi high voltage technician should put a sign on the vehicle to identify it as a high voltage vehicle.
Disable the high voltage system:
Connect the Vehicle Diagnostic Tester.
Select the Guided Fault Finding mode.
Using the GO TO button, select the following menu commands
Function/Component Selection
Body
Electrical Equipment
OBD-capable systems
8C - Battery Regulation Control Module -J840
8C - Battery Regulation Control Module, functions
51 - De-energize the high voltage
Restart the high voltage system
Risk of electrocution
Death or serious bodily injury by electric shock
- The high voltage system may only be restarted by qualified personal (Audi high voltage technicians).
- Make sure the vehicle is energized using the "Guided Fault Finding " on the Vehicle Diagnostic Tester.
- The qualified personal (Audi high voltage technician) restarts the vehicle.
- The Audi high voltage technician should put a sign on the vehicle to identify it as a high voltage vehicle.
Restart the high voltage system:
Connect the Vehicle Diagnostic Tester.
Select the Guided Fault Finding mode.
Using the GO TO button, select the following menu commands
Function/Component Selection
Body
Electrical Equipment
OBD-capable systems
8C - Battery Regulation Control Module -J840
8C - Battery Regulation Control Module, functions
51 - High voltage restart
The engine may start unexpectedly when performing work while the ignition is turned on or when the ready mode is activated and may cause poisoning in enclosed spaces. Be aware of body limbs and/or clothing when clamping or pulling.
Perform the following steps before turning on the ignition:
- Move the selector lever into position P.
- Activate the parking brake.
- Switch off ignition.
- Open the engine hood.
- Connect the charging unit for example Battery Charger VAS 5095A to the battery jump start terminal for the 12V vehicle electrical system
- Switch on the ignition.
-- Charge the vehicle battery, for example, using the Battery Charger VAS5904 in the battery support mode to minimize the number of automatic starts during the test- and measuring procedures while the ready mode is active. Refer to Battery Charger VAS5900 SUPPORT MODE and HIGH VOLTAGE SYSTEM GENERAL WARNINGS and WORKING ON HIGH VOLTAGE VEHICLES .
-- Move the selector level into position "P", activate the parking brake and arrange the necessary tools for testing and measuring procedures that require the ready mode to be active or that require the ignition to be on, so that they cannot come into contact with the turning components in the engine and so that they are not in the vicinity of the turning components of a running engine.
Also move the selector lever into position "P" and activate the parking brake for testing and measuring procedures which require the ignition to be on, but do not require the ready mode to be active.
The ready mode is displayed in the Instrument Cluster Control Module -J285- above the "powermeter". Refer to Owner's Manual.
Activate and deactivate the ready mode. Refer to Owner's Manual (consult the display in the Instrument Cluster Control Module -J285-).
General notes to remove the refrigerant oil from the electrically driven A/C compressor (by flushing, see Flush the Electrically Driven A/C Compressor below (See Fig 1)).
Electrically driven A/C compressors cannot have the refrigerant oil poured out in the same manner as a mechanically driven A/C compressor. There is no drain plug and because it is installed inside defending on the version only a specialized part or no refrigerant oil can be poured out. Depending on the version and the storage of the A/C compressor there remains when pouring our approximately 30 to 80 cm 3 refrigerant oil in the A/C compressor (the electrically driven A/C compressor cannot be turned). For this reason, the A/C compressor is to be flushed to remove the refrigerant oil and to determine the amount of refrigerant oil in the A/C compressor, depending on the complaint. Refer to COMPRESSOR, REPLACING WITHOUT THE NEED FOR FLUSHING REFRIGERANT CIRCUIT .
The refrigerant oil can be removed by flushing in the flow direction for electrically driven A/C compressors (because of the installed valve it is not possible to flush against the flow direction).
To flush, arrange the A/C compressor so that the connection for the refrigerant line on the high pressure side is as low as possible.
- The electrically driven A/C compressor is to be flushed when, there is dirt, too much refrigerant oil is in the refrigerant circuit, or is contaminated (with moisture debris) and to remove refrigerant oil from the A/C compressor. In these cases the refrigerant circuit must also be flushed, so that it will be cleaned and the correct refrigerant oil quantity for the refrigerant circuit can be set. Refer to REFRIGERANT OIL CAPACITIES .
- If the electrically driven A/C compressor is replaced, it is not always necessary to flush the coolant circuit. The amount of refrigerant oil found in the removed A/C compressor can be removed by flushing the A/C compressor. Pour the refrigerant oil out of the new A/C compressor so that only the amount remains (plus 10 cm 3 ) as before the old A/C compressor was flushed out. Refer to COMPRESSOR, REPLACING WITHOUT THE NEED FOR FLUSHING REFRIGERANT CIRCUIT .
- To remove the refrigerant oil from the removed A/C compressor the refrigerant oil must be flushed from the replaced A/C compressors and the removed about measured (Empty the used oil collection from the A/C service station before flushing). Pour the refrigerant oil out of the new A/C compressor so that only the amount or refrigerant oil remains (plus 10 cm 3 ) in the new A/C compressor as the amount of flushed out refrigerant oil from the old A/C compressor. Dispose of the refrigerant oil removed from the defective and the new A/C compressor and poured out refrigerant oil from the new A/C compressor.
- In not enough refrigerant oil can be poured out from the A/C compressor to be installed, flush the new A/C compressor. Fill the A/C compressor to be installed in after flushing with as much new refrigerant oil as was flushed from the removed A/C compressor. Example: from the removed A/C compressor 120 cm 3 refrigerant oil removed in the new A/C compressor to be installed there are 200 cm 3 (Refer to the data plate and REFRIGERANT OIL CAPACITIES .), then from the A/C compressor to be installed 110 cm 3 (120 cm 3 minus 10 cm 3 ) must be poured out so that the refrigerant oil quantity in the refrigerant circuit after installing is correct. If the required amount of refrigerant oil cannot be poured out, flush the A/C compressor to be installed. In the new A/C compressor as much refrigerant oil is to be filled as was flushed out of the old A/C compressor.
Flush the Electrically Driven A/C Compressor
- A/C Service Station
- With electronics and a flushing program, A/C Service Station With Flushing Device. (Refer to Tools; Special Tools and Equipment: A/C and Heating).
- If an A/C service station without a flushing program is used, the procedure must be performed manually (evacuate, flush three times with at least 2 kg refrigerant each and extract refrigerant again, evacuate).
- A/C Service Station Refrigerant Hose
- From high pressure side of A/C service station (mostly colored red) to low pressure side connection of A/C compressor on refrigerant circuit (larger diameter).
- Adapter to the Connection for the Low Pressure Side on the A/C Compressor
- There are different versions depending on vehicle. Refer to ADAPTER FOR ASSEMBLING FLUSHING CIRCUIT .
- Use the adapter from the Refrigerant Circuits Adapter Set 1 VAS6338/1 (here the Refrigerant Circuits Adapter Set 2 - Adapter 41 VAS6338/41).
- Refrigerant Line
- To the A/C compressor connection on the adapter. Refer to item - 3-NOTE:
Only use the refrigerant line when the Refrigerant Circuits Adapter Set 2 - Adapter 41 VAS6338/41 is not available.
If the Refrigerant Circuits Adapter Set 2 - Adapter 41 VAS6338/41 is not available to remove the flushing circuit, for example remove the refrigerant lines to the condenser, from the vehicle (or use a refrigerant line with the part number 7L6 820 744 AD). .
- To the A/C compressor connection on the adapter. Refer to item - 3-
- Electrically-Driven A/C Compressor
- The A/C compressor is flushed in the flow direction (from the low pressure side input to the high pressure side output)
- So that as much refrigerant oil as possible is flushed out from the A/C compressor, the A/C compressor must be positioned so that the high pressure side output is as low as possible
- Refrigerant Line
- To the A/C compressor connection on the adapter. Refer to item - 7-NOTE:
Only use the refrigerant line when the Refrigerant Circuits Adapter Set 2 - Adapter 40 VAS6338/40 is not available.
If the Refrigerant Circuits Adapter Set 2 - Adapter 40 VAS6338/40 is not available to remove the flushing circuit use for example on a refrigerant line with the part number 7L6 820 721 BF or 4G0 260 701 AB. .
- To the A/C compressor connection on the adapter. Refer to item - 7-
- Adapter to the Connection for the High Pressure Side on the Refrigerant Circuit
- There are different versions depending on vehicle. Refer to ADAPTER FOR ASSEMBLING FLUSHING CIRCUIT .
- Use the adapter from the Refrigerant Circuits Adapter Set 1 VAS6338/1 (here the Refrigerant Circuits Adapter Set 2 - Adapter 40 VAS6338/40).
- Charge Hose for Refrigerant Circuit Flushing Device
- From connection to the high pressure side of the A/C compressor on the refrigerant circuit (smaller diameter) to input of refrigerant circuit flushing device.
- Flushing Equipment for Refrigerant Circuits
- There are different versions of the Refrigerant Circuit Flushing Device. (Refer to Tools; Special Tools and Equipment: A/C and Heating).
- With filter, viewing glass, safety valve, heating, refrigerant container etc. (depending on version).
- Depending on the construction of the A/C service station and of refrigerant circuit flushing device, a check-valve may be installed at output of refrigerant circuit flushing device (to guarantee correct direction of refrigerant flow during flushing).
- A/C Service Station Refrigerant Hose
- From the low pressure side of the service station (mostly blue) to the output of the flushing device for refrigerant circuits.