Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 601 (Refrigerant R134A Servicing (1 Of 2)) >> 87 Air Conditioning >> A/C Service Station, Connecting >> Service Station, Connecting With No Connection On Low- And High Pressure Side Of Refrigerant Circuit >> General Information

General Information

WARNING: This page does not describe the selected car, but rather 13 other vehicles, including the 2017 Audi SQ5, 2017 Audi Q5, 2016 Audi SQ5, 2016 Audi Q5, and 2015 Audi SQ5. However, it is still accessible from the selected car via links, so may be relevant.

On the following vehicles, no service connection is provided for the service station on the low-pressure side of the refrigerant circuit; adapters must be used to connect the service station to the refrigerant circuit on these vehicles:

NOTE:

On vehicles with no or inaccessible connection at compressor, remove A/C Refrigerant Low Pressure Switch -F73- (bridge terminals in connector to A/C Refrigerant Low Pressure Switch -F73-) and screw adapter to this connection. Refer to OVERVIEW - REFRIGERANT CIRCUIT (vehicle-specific repair information).

NOTE:

The tools listed below are commercially available or can be obtained from local distributor or importer.

Should it be necessary to measure the pressures at the switch connections on the high-pressure side, use the adapter Adapter Set for Refrigerant Circuit VAG1785/9 and proceed in the same manner.