Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 601 (Refrigerant R134A Servicing (1 Of 2)) >> 87 Air Conditioning >> A/C Service Station, Connecting >> Service Station, Connecting With Connections On Low- And High Pressure Side Of Refrigerant Circuit

Service Station, Connecting With Connections On Low- And High Pressure Side Of Refrigerant Circuit

WARNING: This page does not describe the selected car, but rather 13 other vehicles, including the 2017 Audi SQ5, 2017 Audi Q5, 2016 Audi SQ5, 2016 Audi Q5, and 2015 Audi SQ5. However, it is still accessible from the selected car via links, so may be relevant.

Servicing Station, Connecting for Measuring and Testing

-- Turn off the ignition.

-- Connect the service station to the power supply.

-- Connect the quick-release coupling adapter to the charging hoses of service station (handwheels not screwed in/hand shut-off valve not open).

-- Switch on the service station and evacuate the charging hoses (only necessary if there is air in charging hoses).

-- Switch off the service station.

-- Remove the caps from the service connections (with valve).

-- Connect the service station via the service connections with the quick-release coupling adapters to the vehicle refrigerant circuit.

-- Screw in the handwheel of the quick-release coupling adapters only until the valves are definitely open at the refrigerant circuit connection (observe pressure gauge, do not strain valves).

-- Perform the planned tests and measurements.