Service Station, Connecting With Connections On Low- And High Pressure Side Of Refrigerant Circuit
Servicing Station, Connecting for Measuring and Testing
-- Turn off the ignition.
-- Connect the service station to the power supply.
-- Connect the quick-release coupling adapter to the charging hoses of service station (handwheels not screwed in/hand shut-off valve not open).
-- Switch on the service station and evacuate the charging hoses (only necessary if there is air in charging hoses).
-- Switch off the service station.
-- Remove the caps from the service connections (with valve).
-- Connect the service station via the service connections with the quick-release coupling adapters to the vehicle refrigerant circuit.
-- Screw in the handwheel of the quick-release coupling adapters only until the valves are definitely open at the refrigerant circuit connection (observe pressure gauge, do not strain valves).
-- Perform the planned tests and measurements.