LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 591 (Self-Leveling Suspension (Sedan)) >> 43 Self-Leveling Suspension >> Dynamic Ride Control (DRC) >> Dynamic Ride Control (DRC), System Pressure Checking

Dynamic Ride Control (DRC), System Pressure Checking

WARNING: This page does not describe the selected car, but rather 18 other vehicles, including the 2016 Audi S4, 2016 Audi A4 Quattro, 2016 Audi A4, 2015 Audi S4, and 2015 Audi A4 Quattro. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

DRC Pressure Tester VAS6209/2 bleeding

Use only approved oil for the bleeding procedure. Refer to appropriate FLUID CAPACITY TABLE information.

NOTE:

The charging device DRC Pressure Tester VAS6209/2 must always be bled the first time it is used.

If the charging device DRC Pressure Tester VAS6209/2 still shows a residual pressure greater than 0.5 bar (for example, from a previous reading), bleeding must not be done.

-- To bleed pressure gauge -B- and line section -A-, install special tool as shown in illustration.

Fig 1: Bleeding Pressure Gauge And Line Section
GWWA43-10070Courtesy of AUDI OF AMERICA, LLC
NOTE:

The illustration shows bleeding process by extracting hydraulic fluid using a Hand Vacuum Pump VAS6213.

-- Bleed process must be performed until air bubbles are no longer visible in hose -C-.

-- Disconnect hose -C- and -D- and perform system pressure check.

System pressure check is performed on front shock absorber of corresponding Dynamic Ride Control (DRC) line.

Fig 2: Connecting V.A.S 6209/2 And Remove Dust Cap
GWWA43-10187Courtesy of AUDI OF AMERICA, LLC

-- Remove the cap from the extract/fill valve and connect the DRC Pressure Tester VAS6209/2.

-- Read the system pressure on the DRC Pressure Tester VAS6209/2.

Fig 3: Connecting V.A.S 6209/2 And Remove Dust Cap
GWWA43-10187Courtesy of AUDI OF AMERICA, LLC
NOTE:

The pressure on the DRC Pressure Tester VAS6209/2 increases slowly and takes approximately two minutes. The DRC system pressure can only be read when the needle on the DRC Pressure Tester VAS6209/2 has finally come to a stop.

-- Disconnect the DRC Pressure Tester VAS6209/2 and install the dust cap.

Fig 4: Connecting V.A.S 6209/2 And Remove Dust Cap
GWWA43-10187Courtesy of AUDI OF AMERICA, LLC
NOTE:

A small oil leak at the connection that results from connecting or disconnecting the Dynamic Ride Control (DRC) System pressure tester for Audi RS4 DRC Pressure Tester VAS6209/2 is not critical. Avoid repeating measurements because a small quantity of oil is removed from the system every time the DRC system pressure tester for Audi RS4 DRC Pressure Tester VAS6209/2 is connected. Every connection results in a pressure decrease of approximately 0.3 bar from the previous reading. Multiple repeated measurements decrease system pressure below minimum pressure or failure.

-- If the pressure is not OK, determine the cause and service the system.

Dynamic Ride Control (DRC) System Pressure Values

Pressure values refer to reference temperature of 20 °C.