LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 577 (Heating, Ventilation & Air Conditioning - General & Technical Data (Sedan)) >> 00 General, Technical Data >> Safety Precautions >> Handling Refrigerant Safety Precautions

Handling Refrigerant Safety Precautions

WARNING: This page does not describe the selected car, but rather 18 other vehicles, including the 2016 Audi S4, 2016 Audi A4 Quattro, 2016 Audi A4, 2015 Audi S4, and 2015 Audi A4 Quattro. However, it is still accessible from the selected car via links, so may be relevant.

The assemblies and piping system of the air conditioner are filled with the following refrigerant:

1.1.1.2 Tetrafluorethane (CF3 -CH2 F or CH2 F-CF3 )

Currently, this refrigerant is known under the following trade names R134a, H-FKW 134a, SUVA 134a and KLEA 134a (other trade names may be used in other countries).

The following safety measures should be observed for this refrigerant (additional guidelines apply in individual countries).

If is necessary to open the refrigerant circuit during service work, discharge the refrigerant circuit first. Refer to REFRIGERANT CIRCUIT, DISCHARGING . In doing so, the utmost care is to be taken to avoid contact with liquid refrigerant or refrigerant vapors. Should refrigerant nevertheless escape, avoid inhaling the resultant refrigerant/air mixture.

Extraction-, exhaust system are therefore to be switched on and use made of both rubber gloves and protective goggles.

Reason:

Intensive exposure to refrigerant on unprotected parts of the body will result in frostbite.

WARNING:

It is advised to keep an eye washing station in the work area.

If liquid refrigerant has come in contact with your skin and eyes, immediately flush with cool water for 15 minutes.

Then apply eye drops and consult a doctor immediately even if no pain is felt.

The doctor must be informed, which type of refrigerant caused the freezing.

Should refrigerant come into contact with other parts of the body despite compliance with all the pertinent safety measures, these are similarly to be rinsed thoroughly in cold water without delay for at least 15 minutes.

Although refrigerant does not represent a fire hazard, smoking, welding, soldering and brazing are not permitted in areas exposed to refrigerant.

Reason:

The high temperature of a naked flame or hot objects causes decomposition of refrigerant gas. Inhalation of the resultant toxic decomposition products leads to dry coughing and nausea.