LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 577 (Heating, Ventilation & Air Conditioning - General & Technical Data (Sedan)) >> 00 General, Technical Data >> Repair Information >> Working On The Refrigerant Circuit

Working On The Refrigerant Circuit

WARNING: This page does not describe the selected car, but rather 18 other vehicles, including the 2016 Audi S4, 2016 Audi A4 Quattro, 2016 Audi A4, 2015 Audi S4, and 2015 Audi A4 Quattro. However, it is still accessible from the selected car via links, so may be relevant.

Work on refrigerant system should only be performed in a ventilated rooms (workshops). Ensure that there are no workshop pits, basement staircases or shafts within a five meter circumference. Turn on the existing ventilation systems.

Reason:

The refrigerant emerging is not only colorless and odorless, but also heavier than air and thus displaces oxygen. If refrigerant gas does escape even though all the safety precautions have been followed, there is a risk of suffocating in poorly ventilated areas and in workshop pits - even if it is not noticeable.

NOTE:

The escaping refrigerant/air mixture should not be inhaled, but should be extracted via an existing exhaust-extraction ventilation system.

Do not attempt repair on filled air conditioning systems by soldering, brazing or welding. This pertains also for welding and soldering work on the vehicle, in the event that parts of the climate control system may heat up

Reason:

Exposure to heat creates considerable pressure in the system, which could cause it to burst.

Corrective measure:

Discharge the refrigerant circuit. Refer to REFRIGERANT CIRCUIT, DISCHARGING .

NOTE:

Parts on the A/C that are damaged or leaking cannot be welded or soldered. They must be replaced.

When servicing the A/C system, all open components and pipe connections are to be immediately re-sealed.

Reason:

Moisture will ingress into A/C system components if they are left open for a lengthy period. If this is the case, air conditioners cannot be refilled without having to replace parts of the system.