LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 56 (3.2L - Fuel Injection System - Engine Code: CALA (Sedan)) >> 24 Fuel Injection System >> Removal And Installation >> Oxygen Sensor after Three Way Catalytic Converter -G130- BANK 1 RIGHT

Oxygen Sensor after Three Way Catalytic Converter -G130- BANK 1 RIGHT

WARNING: This page is about a different car, the 2009 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

Removing 

-- Pull rear engine cover off -arrows-.

Fig 1: Pulling Rear Engine Cover Off
GWWA10-1515Courtesy of AUDI OF AMERICA, LLC

-- Free up the fuel supply line -4- and hose connection -1- to the EVAP canister on the air filter housing and on the air guide tube.

Fig 2: Open Expanding Clamps
GWWA10-10839Courtesy of AUDI OF AMERICA, LLC

-- Remove the vacuum hose -2- from the air guide hose.

-- Remove the air guide hose by loosening the hose clamp -3- and opening the clips -arrows-.

-- Disconnect the electrical connector -5- for the oxygen sensor after three way catalytic converter.

Fig 3: Identifying Electrical Connectors
GWWA28-10009Courtesy of AUDI OF AMERICA, LLC

-- Remove the oxygen sensor after three way catalytic converter -2- using a tool from the 3337.

Fig 4: Oxygen Sensors Location, Cylinder Bank 1 (right)
GWWA24-10567Courtesy of AUDI OF AMERICA, LLC
NOTE:

The installation location is shown with the engine removed.

Installing 

Installation is performed in the reverse order of removal, noting the following:

NOTE:

Coat new oxygen sensors with an assembly paste.

When installing the previous oxygen sensor, coat the thread with hot bolt paste.

Assembly paste or hot bolt paste must not enter the slots on the oxygen sensor body.

Always install the oxygen sensor wire in the same location so it does not come into contact with the exhaust pipe.

During installation, all cable ties must be installed at the same location.