Expansion Valve, Removing And Installing: Installing
Installation is done is reverse order, observe the following:
-- Clean the connection pipes -C- and -E- leading to the evaporator and the expansion valve connections, and check for damage.
The expansion valve is available in different versions (same housing but a different control characteristic). Therefore, to ensure the exact allocation.
Follow the instructions for installing the O-rings. Refer to REFRIGERANT CIRCUIT SEALS .
-- Replace the O-ring seals -B- and -F-. Allocate correct version.
-- Coat the O-ring seals lightly with refrigerant oil before installing. Refer to REFRIGERANT CIRCUIT SEALS .
-- Make sure the retaining plate -D- fits correctly on the connection pipes -C- and -E- leading to the evaporator.
-- Tighten the bolts -G-.
- Tightening specification: 10 Nm.
-- Install the refrigerant line with inner heat exchanger. Refer to REFRIGERANT LINES WITH INNER HEAT EXCHANGER, REMOVING AND INSTALLING .
-- Evacuate the refrigerant circuit and fill it. Refer to USING SERVICE STATION .
On vehicles with a high voltage system (hybrid vehicles)
-- Visually inspect the high voltage components -D- and high voltage cables -E- after completing the work procedures and before installing the plenum chamber cover -B-. Refer to HIGH VOLTAGE SYSTEM GENERAL WARNINGS for Hybrid .
-- Electrical connections and routing. Refer to the appropriate SYSTEM WIRING DIAGRAM.
-- Energize the power supply to the high voltage system. Refer to HIGH VOLTAGE SYSTEM, DE-ENERGIZING .
All vehicles
-- Install the remaining removed components.
-- Turn on the ignition.
-- Check the DTC memory for the Climatronic Control Module -- display and control head and erase any displayed malfunctions, if necessary using the Vehicle Diagnostic Tester in the "Guided Fault Finding" function.
-- Operate the A/C system after filling the refrigerant circuit. Refer to A/C SYSTEM, STARTING OPERATION AFTER FILLING REFRIGERANT CIRCUIT .
Observe the information regarding operating the A/C system after filling. Refer to A/C SYSTEM, OPERATING AFTER CHARGING . After charging the A/C system before activating the A/C system.