LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 527 (Charging System & Cruise Control System (Starter, Generator & Cruise Control) (Sedan)) >> 27 Starter, Generator And Cruise Control >> Battery, Charging >> Battery Charger VAS5906 >> BATTERY, CHARGING WITH Battery Charger VAS5906

BATTERY, CHARGING WITH Battery Charger VAS5906

WARNING: This page does not describe the selected car, but rather 18 other vehicles, including the 2016 Audi S4, 2016 Audi A4 Quattro, 2016 Audi A4, 2015 Audi S4, and 2015 Audi A4 Quattro. However, it is still accessible from the selected car via links, so may be relevant.
WARNING:

Risk of injury. Follow all warning messages and safety precautions. Refer to WARNINGS AND SAFETY PRECAUTIONS .

WARNING:

Do not check or charge a Battery -A- when the visual indicator has >>no color or is bright yellow<<. Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These Batteries -A- must be replaced.

Special tools and workshop equipment required 

Procedure 

-- Place the Battery Charger VAS5906 in the engine compartment or under the vehicle.

-- Connect the Battery Charger VAS5906 to the power supply.

The Battery Charger VAS5906 is in idle, the display comes on when it is "ready to be used".

WARNING:

Risk of injury. Follow all warning messages and safety precautions. Refer to WARNINGS AND SAFETY PRECAUTIONS .

CAUTION:
  • Turn off the ignition and all electrical equipment.
  • Remove the key.

-- Connect the red charge terminal (+) to the positive terminal of the Battery -A-.

NOTE:

On vehicles with a Start/Stop function and an installed Battery Monitoring Control Module -J367-, the black charge terminal (-) must be connected to the body ground. The Start/Stop system will malfunction when it is connected to the Battery -A- negative terminal.

-- Connect the black charge terminal (-) to the negative terminal of the Battery -A- /negative connector.

The charging process starts after approximately two seconds.

LEDs show the Battery -A- charge level. When all the lamps are on, the Battery -A- is charged.

When the Battery -A- is completely charged, the Battery Charger VAS5906 automatically switches to maintenance charging.

CAUTION:

Sparks can result if the charging terminals are removed too early. End the charging process by pressing the START/STOP  button.

Battery -A- Charging, Ending

-- Press the START/STOP  -button.

-- Remove the charging clamps from the battery terminals.

-- Disconnect the Battery Charger VAS5906 from the power.