Water Content

WARNING: This page does not describe the selected car, but rather 18 other vehicles, including the 2016 Audi S4, 2016 Audi A4 Quattro, 2016 Audi A4, 2015 Audi S4, and 2015 Audi A4 Quattro. However, it is still accessible from the selected car via links, so may be relevant.

Only very small amounts of water are soluble in liquid refrigerant. On the other hand, refrigerant vapor and water vapor mix in any ratio.

Any water in the refrigerant circuit will be entrained in droplet form once the dryer in the receiver or reservoir has absorbed as little as approximately 7g of water. This water flows as far as the nozzle of the expansion valve or restrictor and turns to ice, the A/C system no longer has a cooling effect.

Water destroys the air conditioner as it combines with other impurities at high pressures and temperatures to form acids.