ACC, CALIBRATING, CALIBRATION PROCEDURE WITH Setting Device Basic Set VAS6430/1
Special tools and workshop equipment required
- Vehicle Diagnostic Tester
- Setting Device Basic Set VAS6430/1
- ACC Adjuster VAS6190/2
- Wheel Alignment Computer
The Setting Device Basic Set VAS6430/1 may have to be adapted for the adjustment procedure. Refer to Setting Device Basic Set VAS6430/1 CONVERTING, FOR THE CALIBRATION PROCEDURE .
Before driving the vehicle onto the alignment stand, check if there is enough space between the vehicle and the Setting Device Basic Set VAS6430/1. The distance between the Setting Device Basic Set VAS6430/1 and the vehicle must be 120 cm ± 5 cm.
If there is not enough space, drive vehicle the backward on the alignment stand in order to be able to use the space.
- Before beginning the adjustment, check the DTC memory and correct any malfunctions present.
The calibration procedure is described here using the Setting Device Basic Set VAS6430/1. However the ADC Adjustment Fixture VAS6041 and the ADC Reflector Mirror VAS6041/1 can also be used.
Do not perform the steps under "Calibration procedure without a previous axle alignment" if an axle alignment has already been performed.
Calibration procedure without a previous axle alignment
-- Connect the battery charger. Refer to Refer to BATTERY, CHARGING ..
-- Select the ACC calibration button on the alignment computer.
-- Mount the quick clamps to the rear wheels.
-- Mount the measurement sensor to the rear wheels.
-- Perform a wheel run-out compensation and the rear wheels.
The Setting Device Basic Set VAS6430/1 must not be moved on the calibration beam.
Calibration procedure with or without a previous axle alignment
-- Remove the right front air intake grille. Refer to OVERVIEW - BUMPER COVER .
RS Models:
-- Remove the front bumper cover. Refer to BUMPER COVER, REMOVING AND INSTALLING .
-- Remove the air guide to the coolant auxiliary cooler. .
All Models:
-- Remove all dirt on the sensor lens.
-- Position Setting Device Basic Set VAS6430/1 at a distance -A- of 120 cm ± 5 cm from sensor lens to mirror surface.
- Place a toolbox or container weighing approximately 5 to 7 kg on the Setting Device Basic Set VAS6430/1 before installing the measuring sensors and moving the mirror on the calibration beam.
- If weight is not put on the Setting Device Basic Set VAS6430/1, it could tip over when the mirror is moved and/or when the measuring sensors are installed.
-- Load the ACC Setting Device VAS6190 with the weight -arrow- as shown in the illustration.
-- Mount the front wheel measuring sensors -1- onto the Setting Device Basic Set VAS6430/1.
-- In area -A-, bring item -2- on rotary knob into alignment with marking on mirror (number 2 on rotary knob must face toward vehicle).
-- Now align the Setting Device Basic Set VAS6430/1 by sliding it sideways -arrows B- so that the laser beam is horizontally centered on the senor lens.
-- Bring the bubble levels -2- on the Setting Device Basic Set VAS6430/1 into balance using adjustment screws -1-.
-- Adjust vertical slits -4- on Setting Device Basic Set VAS6430/1 so that laser beam is centered vertically on sensor lens.
-- Adjust the same front axle individual toe settings using fine adjustment screw -3-.
-- The difference between individual toe values must be less than 6' or they must be the same.
-- Bring bubbles -2- on measurement sensor -1- into balance.
-- Now using the laser beam -3- on the Setting Device Basic Set VAS6430/1, check if the laser beam contacts the sensor lens.
If the laser beam still meets the sensor lens at this step after adjusting the same individual toe values, the Setting Device Basic Set VAS6430/1 is aligned correctly (positioned).
If the laser beam does not meet the sensor lens, the Setting Device Basic Set VAS6430/1 must be aligned again.
-- Connect the Vehicle Diagnostic Tester.
The Vehicle Diagnostic Tester is ready for operation when the operating modes are displayed.
-- Turn on the ignition.
-- Touch Guided Fault Finding .
-- Select in succession:
- Brand
- Type
- Model year
- Version
- Engine Code
-- Confirm data entered.
Wait until the Vehicle Diagnostic Tester has checked all the vehicle control module.
-- Press the Go to button and select "Function/component selection".
-- Select the corresponding program in "Guided Functions ".
Now follow instructions on screen to perform adjustment.
-- Turn the ACC Adjuster VAS6190/2 in direction of arrow -A or B- and use the upper screw -2- and the lower screw -1- for precision adjustment in "Guided Fault Finding ".
The ACC adjustment is confirmed when "output diagnostic test complete" appears in the Vehicle Diagnostic Tester.
-- Switch ignition off.
-- Disconnect the Vehicle Diagnostic Tester from the diagnostic connector.
-- Disconnect the battery charger. Refer to BATTERY, CHARGING .
RS Models:
-- Install the air guide to the coolant auxiliary cooler. .
-- Install the front bumper cover. Refer to BUMPER COVER, REMOVING AND INSTALLING .
All Models:
-- Install the air intake grille. Refer to OVERVIEW - BUMPER COVER .
Special tools and workshop equipment required
- Setting Device Basic Set VAS6430/1
- ACC Adjuster VAS6190/2
- Vehicle Diagnostic Tester
- Wheel Alignment Computer
Before driving the vehicle onto the alignment stand, check if there is enough space between the vehicle and the Setting Device Basic Set VAS6430/1. The distance between the Setting Device Basic Set VAS6430/1 and the vehicle must be 120 cm ± 5 cm.
If there is not enough space, drive vehicle the backward on the alignment stand in order to be able to use the space.
Before performing the calibration procedure, check the position of the calibration mirror and adjust it if necessary.
The Setting Device Basic Set VAS6430/1 must be adapted before the adjustment procedure. If this is done during the adjustment procedure, the pre-calibration on the Setting Device Basic Set VAS6430/1 must be repeated.
- Before beginning the adjustment, check the DTC memory and correct any malfunctions present.
The adjustment procedure is described here using the Setting Device Basic Set VAS6430/1.
Do not perform the steps under "Calibration procedure without a previous axle alignment" if an axle alignment has already been performed.
Calibration procedure without a previous axle alignment
-- Connect the battery charger. Refer to BATTERY, CHARGING .
-- Select the ACC calibration button on the alignment computer.
-- Mount the quick clamps to the rear wheels.
-- Mount the measurement sensor to the rear wheels.
-- Perform a wheel run-out compensation and the rear wheels.
The Setting Device Basic Set VAS6430/1 must not be moved on the calibration beam.
Calibration procedure with or without a previous axle alignment
-- Remove the right front air intake grille. Refer to OVERVIEW - BUMPER COVER .
RS Models:
-- Remove the front bumper cover. Refer to BUMPER COVER, REMOVING AND INSTALLING .
-- Remove the air guide to the coolant auxiliary cooler. .
All Models:
-- Remove all dirt on the sensor lens.
-- If necessary, remove the mirror installed at the center and install it all the way at the right near the vertical slits.
-- Position Setting Device Basic Set VAS6430/1 at a distance -A- of 120 cm ± 5 cm from sensor lens to mirror surface.
-- Mount the front wheel measuring sensors -1- onto the Setting Device Basic Set VAS6430/1.
-- In area -A-, bring item -2- on rotary knob into alignment with marking on mirror (number 2 on rotary knob must face toward vehicle).
-- Now align the Setting Device Basic Set VAS6430/1 by sliding it sideways -arrows B- so that the laser beam is horizontally centered on the senor lens.
-- Level the bubble levels -A- and -B- on the Setting Device Basic Set VAS6430/1 using the adjusting screws -1-, -2- and -3-.
-- Adjust the mirror -4- using the crank -arrow- on the Setting Device Basic Set VAS6430/1 so the laser beam is vertically centered on the sensor lens.
-- Adjust the same front axle individual toe settings using fine adjustment screw -5-.
-- The difference between individual toe values must be less than 6' or they must be the same.
-- Bring bubbles -2- on measurement sensor -1- into balance.
-- Now using the laser beam -3- on the Setting Device Basic Set VAS6430/1, check if the laser beam contacts the sensor lens.
If the laser beam still meets the sensor lens at this step after adjusting the same individual toe values, the Setting Device Basic Set VAS6430/1 is aligned correctly (positioned).
If the laser beam does not meet the sensor lens, the Setting Device Basic Set VAS6430/1 must be aligned again.
-- Connect the Vehicle Diagnostic Tester
The Vehicle Diagnostic Tester is ready for operation when the operating modes are displayed.
-- Turn on the ignition.
-- Touch Guided Fault Finding .
-- Select in succession:
- Brand
- Type
- Model year
- Version
- Engine Code
-- Confirm data entered.
Wait until the Vehicle Diagnostic Tester has checked all the vehicle control module.
-- Press the Go to button and select "function/component selection".
-- Select the corresponding program in "Guided Functions ".
Now follow instructions on screen to perform adjustment.
-- Turn the ACC Adjuster VAS6190/2 in direction of -arrow A or B- and use the upper screw -2- and the lower screw -1- for precision adjustment in "Guided Fault Finding ".
The ACC adjustment is confirmed when "output diagnostic test complete" appears in the Vehicle Diagnostic Tester.
-- Switch ignition off.
-- Disconnect the Vehicle Diagnostic Tester from the diagnostic connector.
-- Disconnect the battery charger. battery charger. Refer to BATTERY, CHARGING .
RS Models:
-- Install the air guide to the coolant auxiliary cooler. .
-- Install the front bumper cover. Refer to BUMPER COVER, REMOVING AND INSTALLING .
All Models:
-- Install the air intake grille. Refer to OVERVIEW - BUMPER COVER .