Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 45 (Electrical Equipment - General Information) >> 27 - Battery, Starter, Generator, Cruise control >> Battery, Charging >> Totally Discharged Batteries, Charging >> Totally Discharged Batteries, Charging

Totally Discharged Batteries, Charging

WARNING: This page does not describe the selected car, but rather 16 other vehicles, including the 2009 Audi S4, 2009 Audi A4, 2008 Audi S4, 2008 Audi RS 4, and 2008 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.
CAUTION: Risk of injury from battery acid.
  • Prior to handling or servicing batteries, read, understand and observe the Warnings and Safety Measures for lead-acid batteries for lead-acid batteries → Safety Precautions  !
  • Wear protective eyewear and clothing → 27 - Battery, Starter, Generator, Cruise control  .
  • On non-maintenance-free batteries, the sealing plugs must be installed tightly.
  • Provide sufficient ventilation.
  • If the magic eye has no color or is light yellow, the battery may not be tested or charged. Jump starting must not be used! There is a risk of explosion during testing, charging or jump starting. The battery must be replaced.
  • DO NOT battery test batteries which are gassing. Otherwise there is a risk of explosion.
  • Rapid-charging batteries → Battery, Quick Charging .
  • Dispose of electrolyte (sulfuric acid/water mixture) properly! Waste electrolyte must only be disposed of in appropriate waste disposal sites. Refer to local regulations pertaining to electrolyte disposal.
  • The following notes and procedures must be followed to ensure correct charging.
CAUTION: Risk of severely discharged batteries freezing.
  • Severely discharged batteries freeze at low temperatures, the housing can crack.
  • Batteries that have frozen must no longer be used.

Prerequisite 

Procedure 

Severely discharged (sulfated) batteries must be charged using a low charging current:

NOTE:
  • The Midtronics Diagnostic Conductance Charging Station INC-940 automatically detects severely discharged batteries and carefully starts the charging procedure with a low charging current. The charge current is automatically adjusted to the battery charge state.
  • In order to initiate charging procedure, battery voltage must be at least 0.6 V!
CAUTION: Risk of damaging severely discharged batteries.
  • Do not quick charge severely discharged batteries.
NOTE: