Refrigerant Circuit with Expansion Valve
HP (HD) High pressure side of refrigerant circuit
LP (ND) Low pressure side of refrigerant circuit
| Component | Refrigerant state | Pressure (bar) | Temperature in degrees Celsius |
| 1 Evaporator, from inlet to outlet | Vapor | approx. 1.2 bar 1 | approx. -7 ° C 2 |
| 2 Expansion valve | Liquid, released as vapor | approx. 14 bar | approx. + 55 ° C (HP- side), reduces to -7 ° C (LP-side) |
| 3 High pressure switch / high pressure sensor | Liquid | approx. 14 bar | approx. + 55 ° C |
| 4 Service connection, HP (HD) side and 5 fluid reservoir | Liquid | approx. 14 bar | approx. + 55 ° C |
| 6 Condenser | Gas (at inlet) to vapor to liquid (at outlet) | approx. 14 bar | From approx. + 65 ° C (at input) to approx. + 55 ° C (at outlet) |
| 7 pressure relief valve and 8 compressor, HP (HD) side | Gas | approx. 14 bar | approx. + 65 ° C |
| 9 Compressor, LP (ND) side | Gas | approx. 1.2 bar 1 | approx. -1 ° C 2 |
| 10 Pre-volume (not present in all vehicles) and 11 Service connection, LP (ND) side | Gas | approx. 1.2 bar 1 | approx. -1 ° C 2 |
* 1 - The pressure in a refrigerant circuit with regulating compressor is maintained at approx. 2 bar absolute pressure (corresponds to approx. 1 bar positive pressure) despite varying heat transfer and fluctuating engine speeds. This however only applies within the output range of the compressor. If the output limits of the compressor are exceeded, the pressure will rise → Refrigerant Circuit, Checking Pressures with A/C Service Station .
* 2 - The temperature in a refrigerant circuit with regulating compressor is maintained within the regulating range of the compressor despite varying heat transfer and fluctuating engine speeds. This however only applies within the output range of the compressor. If the output limits of the compressor are exceeded, the temperature will rise → Refrigerant Circuit, Checking Pressures with A/C Service Station .
- Non self-regulating compressors are switched off by the relevant control module via the A/C Compressor Regulator Valve N280 at evaporator temperatures below 0 C.
- On vehicles with A/C Compressor Regulator Valve N280 the pressure on the low pressure side is altered by actuating the valve.
- Temperature and pressure in the refrigerant circuit in vehicles with two evaporators and two expansion valves correspond to those in vehicles with only one evaporator and one expansion valve (parallel switching).
Arrows show direction of refrigerant flow.
HD- High Pressure (HP) side of refrigerant circuit.
ND- Low Pressure (LP) side of refrigerant circuit.
1 - Evaporator
2 - Expansion valve
3 - High pressure switch / high pressure sensor
- Different versions depending on vehicle
4 - Service connection, HP (HD) side
5 - Receiver
- Different versions depending on vehicle
6 - Condenser
7 - Pressure relief valve
8 - Compressor, HP (HD) side
9 - Compressor, LP (ND) side
10 - Pre-volume
- Not present on all vehicles
11 - Service connection, valve LP (ND)