LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 40 (Refrigerant R134A - Servicing) >> 87 - Air conditioning >> General Information >> Pressure Vessels, Handling

Pressure Vessels, Handling

WARNING: This page does not describe the selected car, but rather 17 other vehicles, including the 2009 Audi S4, 2009 Audi A4, 2008 Audi S4, 2008 Audi RS 4, and 2008 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.

Secure upright cylinders to stop them falling over and cylinders lying flat to stop them rolling away.

If dropped, the vessels could be so severely deformed that they rupture. The refrigerant evaporates immediately, liberating considerable force. Flying fragments of cylinders can cause severe injuries.

Valves may break off if cylinders are not properly transported. To protect the valves, cylinders are only to be transported with protective cap screwed on.

High temperatures may occur in such areas. High temperatures are also accompanied by high pressures and the maximum permissible vessel pressure may be exceeded.

Do not heat in excess of 50 C 

To avoid possible risk, pressure vessel regulations specify that vessels are not to be heated to in excess of 50 C.

Do not heat in an uncontrolled manner 

Do not heat with a naked flame under any circumstances. Localized overheating can cause structural changes in the vessel material, which then reduce its ability to withstand pressure. There is also a danger of refrigerant decomposition due to localized overheating.

Seal empty vessels 

Empty refrigerant vessels must always be sealed to prevent the ingress of moisture. Moisture causes corrosion of steel vessels. This weakens the vessel walls. In addition, rust particles penetrating into refrigeration systems from vessels will cause malfunctioning.