Refrigerant lines on compressor, removing and installing: Installing
WARNING: This page does not describe the selected car, but rather 17 other vehicles, including the 2009 Audi S4, 2009 Audi A4, 2008 Audi S4, 2008 Audi RS 4, and 2008 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.
Install in reverse order, paying attention to the following:
- Check type of seal at connections and refrigerant lines (must be designed for same type of seal) → Connections of refrigerant lines to the components (different versions)
- Replace O-rings - D - and - E - ;
- Tighten bolts - B - to 25 Nm.
- Tighten bolt - A - to 25 Nm.
NOTE:
- Tighten bolts - B - and then secure clip - C - with bolt - A -.
- Use must not be made of O-rings from caps of replacement compressor connections.
- After attaching, check routing of refrigerant lines - A -. They must be inserted in brackets - B - provided and not make contact with other components.