Indicated on display (function selection):

Vehicle system - test HELP
Select function XX

Indicated on display (function selection):

Basic setting
Enter display group number XXX

Indicated on display (function selection):

System in basic setting 8 off (4 on) ->
not oper. Pump off XXX mbar test off

Indicated on display (function selection):

System in basic setting 8 on (8 off) ->
Oper./not oper. Pump on XXX mbar test on

The pump evacuates the brake booster. The diagnosis of the brake booster system runs in parallel in the control module. The system passes the test if the pressure in the brake booster reaches the shut-off threshold within the time limit set by the diagnostic function (max. 20 sec).

Indicated on display (function selection):

System in basic setting 8 on (8 off) ->
not oper. Pump off XXX mbar system OK

or:

Indicated on display (function selection):

System in basic setting 8 ->
not oper. Pump off XXX mbar Syst.n.OK

If the test shows the system is not OK, read out the DTC memory and repair the malfunction (ignition must be switched off!).