LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 33 (Brake System) >> 47 - Brakes - Hydraulic components >> Brake system vacuum pump V192 >> Brake system vacuum pump V192 , checking

Brake system vacuum pump V192 , checking

WARNING: This page does not describe the selected car, but rather 17 other vehicles, including the 2009 Audi S4, 2009 Audi A4, 2008 Audi S4, 2008 Audi RS 4, and 2008 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.

Special tools, testers and auxiliary items required 

Fig 1: Identifying Vehicle Diagnosis, Testing And Information System VAS 5051
GW00000410Courtesy of VOLKSWAGEN UNITED STATES, INC.

Procedure 

Fig 2: Special Tool - VAS 5051 & On Switch
GW00000265Courtesy of VOLKSWAGEN UNITED STATES, INC.

The tester may need up to 3 minutes before it is ready for operation.

The control module identification and coding will appear at top right of display.

The following information will appear at the bottom of the display:

Basic setting  
  Not operated
  Pump off
  xxx mbar
  Test off

The following information will appear at bottom of display:

Basic setting  
  Not operated
  Pump on
  xxx mbar
  Test on

Do not press brake pedal again once test has been activated.

The Brake System Vacuum Pump V192 supplies vacuum to brake booster. The diagnosis of the brake booster system runs in the control module at the same time.

The system passes the test if the pressure in the brake booster reaches the shut-off threshold within time limit set by diagnostic function.

The following information will appear at bottom of display:

Basic setting  
  Not operated
  Pump off
  xxx mbar
  Syst. OK

The system fails the test if pressure in brake booster does not reach shut-off threshold within time limit set by diagnostic function.

The following information will appear at bottom of display:

Basic setting  
  Not operated
  Pump off
  xxx mbar
  Syst.n.OK