| DTC | Error Message | Diagnostic Procedure | Malfunction Criteria and Threshold Value | Secondary Parameters with Enable Conditions | Monitoring Time Length | Frequency of checks, MIL Illum |
|---|---|---|---|---|---|---|
| P0705 | Transmission Range Sensor Circuit Malfunction (PRNDL Input) |
|
|
0.1 Seconds |
|
|
| P0706 | Transmission Range Sensor A Circuit Range/Performance |
|
4 bit position code, incorrect |
|
0.1 Seconds |
|
| P0707 | Transmission Range Sensor Circuit Low |
|
|
0.1 Seconds |
|
|
| P0708 | Transmission Range Sensor Circuit High |
|
|
0.1 Seconds |
|
|
| P0710 | Transmission Fluid Temperature Sensor A Circuit |
|
Sensor short circuit:
|
1.5 Seconds |
|
|
| P0711 | Transmission Fluid Temperature Sensor A Circuit Range/Performance |
|
Discontinual temperature:
|
|
1.5 Seconds |
|
| P0712 | Transmission Fluid Temperature Sensor A Circuit Low |
|
Circuit low:
|
1.5 Seconds |
|
|
| P0713 | Transmission Fluid Temperature Sensor A Circuit High |
|
Circuit high:
|
1.5 Seconds |
|
|
| P0714 | Transmission Fluid Temperature Sensor A Circuit Intermittent |
|
Circuit high:
|
1.5 Seconds |
|
|
| P0716 | Input/Turbine Speed Sensor A Circuit Range/Performance |
|
Signal higher or lower than threshold
|
Higher:
|
0.6 Seconds |
|
| P0717 | Input/Turbine Speed Sensor A Circuit No Signal |
|
Hardware detection | Sensor supply, OK | 0.6 Seconds |
|
| P0721 | Output Speed Sensor Circuit Range/Performance |
|
|
|
|
|
| P0722 | Output Speed Sensor Circuit No Signal |
|
Hardware detection | Sensor supply, OK | 0.6 Seconds |
|
| P0727 | Engine Speed Input Circuit No Signal |
|
CAN message signal error flag, =1 |
|
1 Second |
|
| P0741 | Torque Converter Clutch Circuit Performance or Stuck Off |
|
Rate of (setting of nominal value) - actual value, > 50 RPM | Status of clutch, closed or closed loop control | 15 Seconds |
|
| P0746 | Pressure Control Solenoid 'A Performance or Stuck Off |
|
PWM hardware detection, 0 or 100% |
|
0.05 Seconds |
|
| P0747 | Pressure Control Solenoid 'A Stuck On |
|
PWM hardware detection, 0 or 100% |
|
0.05 Seconds |
|
| P0748 | Pressure Control Solenoid 'A Electrical |
|
|
|
0.05 Seconds |
|
| P0751 | Shift Solenoid A Performance or Stuck Off |
|
|
|
0.05 Seconds |
|
| P0752 | Shift Solenoid Stuck On |
|
|
|
0.05 Seconds |
|
| P0754 | Shift Solenoid "A" Intermittent |
|
|
|
0.05 Seconds |
|
| P0776 | Pressure Control Solenoid B Performance or Stuck Off |
|
PWM hardware detection, 0 or 100% |
|
0.05 Seconds |
|
| P0777 | Pressure Control Solenoid B Stuck On |
|
PWM hardware detection, 0 or 100% |
|
0.05 Seconds |
|
| P0778 | Pressure Control Solenoid B Electrical |
|
|
|
0.05 Seconds |
|
| P0796 | Pressure Control Solenoid C Performance or Stuck Off |
|
PWM hardware detection, 0 or 100% |
|
0.05 Seconds |
|
| P0797 | Pressure Control Solenoid C Stuck On |
|
PWM hardware detection, 0 or 100% |
|
0.05 Seconds |
|
| P0798 | Pressure Control Solenoid C Electrical |
|
|
|
0.05 Seconds |
|
| P0889 | TCM Power Relay Sense Circuit Range/Performance |
|
FET drive, not possible |
|
0.03 Seconds |
|
| P0890 | TCM Power Relay Sense Circuit Low |
|
|
|
0.03 Seconds |
|
| P0891 | TCM Power Relay Sense Circuit High |
|
Hardware detection |
|
0.03 Seconds |
|
| P0892 | TCM Power Relay Sense Circuit Intermittent |
|
Hardware detection |
|
0.03 Seconds |
|