Display groups "026" and "027"
WARNING: This page is about a different car, the 2008 Audi S4, 2008 Audi RS 4, and 2008 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.
Ambient conditions under which pressure in refrigerant circuit was last not OK
NOTE:
- If no malfunction has been detected since the DTC memory was last erased, the display zones of the display groups "026" and "027 " indicate, depending on the version of the operating and display module, Climatronic Control Module J255, "erased" for example.
| Display group "026" | ||
|---|---|---|
| Display field | Meaning | Remarks |
| 1 | Deactivation fault location
|
|
|
|
|
NOTE:
- The display "0819" is the DTC code for the malfunction location High Pressure Sensor G65.
- Display field "1" may, depending on the hardware/software version of the operating and display module, Climatronic Control Module J255, display a different DTC code instead of "0819". This DTC code can then be ignored.
| Display group "026" | ||
|---|---|---|
| Display field | Meaning | Remarks |
| 2 | Pressure in bar (absolute pressure) in refrigerant circuit when fault occurred, calculated by way of pressure signal from High Pressure Sensor G65 |
|
| 3 | Activation in % of Coolant Fan V7 when fault occurred (specified output requested by operating and display module, Climatronic Control Module J255) |
|
| 4 | Activation in % transmitted from relevant engine control module to Coolant Fan Control (FC)Control Module J293 for Coolant Fan V7 when fault occurred (feedback of specified output requested)
|
|
| Display group "027" | ||
|---|---|---|
| Display field | Meaning | Remarks |
| 1 | Calculated ambient temperature in °C when fault occurred, transmitted by Instrument Cluster Control Module J285 |
|
| 2 | Vehicle speed in km/h when fault occurred, transmitted by Instrument Cluster Control Module J285 |
|
| 3 | Coolant temperature in °C when fault occurred, transmitted by Instrument Cluster Control Module J285 |
|
| 4 | Display field not used | |