LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 1499 (Heating & Air Conditioning (On Board Diagnostic)) >> 01 On Board Diagnostic (OBD) >> Read Measuring Value Block (function 08) >> Measuring value blocks from display group "020" >> Display group "028"

Display group "028"

WARNING: This page is about a different car, the 2008 Audi S4, 2008 Audi RS 4, and 2008 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.

Display of adaptation channels for which setting has been changed by way of "Adaptation" function 

NOTE:
  • This display group is not used with operating and display modules, Climatronic Control Module J255 up to part number index "AH" (installed in vehicles up to VIN 399999 in Model Year 2005 for Saloon and Avant; gradual introduction for the Cabrio in week 46/04 without prior specification of any particular VIN ).
  • A maximum of 4 altered adaptation channels are displayed with operating and display modules, Climatronic Control Module J255 with part number index "AJ" onwards (installed in vehicles as of VIN 400000 in Model Year 2005 for Saloon and Avant; gradual introduction for the Cabrio in week 46/04 without prior specification of any particular VIN ). If changes have been made to the factory setting in more than 4 adaptation channels, these are no longer displayed (if applicable, reset adaptation of all adaptation channels by way of "Adaptation" function in adaptation channel "20" to factory setting → Climatronic Control Module J255, Adaptation (function 10) ).
Display field Meaning Remarks
1
  • Display = "0" (or display zone blank)
  • No changes have been made to adaptation or all changes made have been reset to factory setting by way of "Adaptation" function in adaptation channel "20"
  • Display = "XX"
  • The display sequence for the adaptation channels with altered setting is governed by the adaptation performed and the version of the operating and display module, Climatronic Control Module J255
2 to 4
  • Display = "0" (or display zone blank)
  • No (or max. one, two or three) change(s) made to adaptation or all changes made have been reset to factory setting by way of "Adaptation" function in adaptation channel "20"
  • Display = "XX"
  • The display sequence for the adaptation channels with altered setting is governed by the adaptation performed and the version of the operating and display module, Climatronic Control Module J255