LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 1499 (Heating & Air Conditioning (On Board Diagnostic)) >> 01 On Board Diagnostic (OBD) >> Read Measuring Value Block (function 08) >> Measuring value blocks from display group "011" through "020" >> Display group "018"

Display group "018"

WARNING: This page is about a different car, the 2008 Audi S4, 2008 Audi RS 4, and 2008 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.

Time period transmitted by Instrument Cluster Control Module J285 for "Ignition switched off" and ignition key assignment transmitted, windshield wiper signal transmitted by Steering Column Electronic Systems Control Module J527 and operating status transmitted by Fresh Air Blower Control Module J126 for Fresh Air Blower V2 

Display field Meaning Remarks
1 Time transmitted by Instrument Cluster Control Module J285 for period between ignition being switched off and on
  • Display = "00:00 to XX:XX h"
  • Ignition switched off time (standing time) in hours and minutes
  • Data are transmitted via the CAN-Bus comfort system
NOTE:
  • If an "ignition off time" signal is not detected by the operating and display module, Climatronic Control Module J255 when the ignition is switched on, the operating and display module, Climatronic Control Module J255 assumes a standing time of more than 4 hours and the engine temperature is taken to be the same as the ambient temperature. In heating mode, for example, this may lead to delayed start-up of the fresh-air blower despite the engine being warm. The Outside Air Temperature Display G106 in the instrument cluster may also display incorrect ambient temperature values.
  • After a standing time of 4 hours, the operating and display module, Climatronic Control Module J255 assumes for temperature calculation purposes that all vehicle components are at ambient temperature.
  • Depending on the hardware/software version of the operating and display module, Climatronic Control Module J255, the display in this zone is limited to a value stored in the operating and display module, Climatronic Control Module J255 (e.g. 3:59 h, 04:46 h) or the actual time is displayed.
  • After connection of the Battery A, the Instrument Cluster Control Module J285 may effect restart (reset) and may therefore not be able to transmit a time signal when the ignition is first switched on. If applicable, switch off ignition for several minutes and check time period displayed after switching ignition back on.
Display field Meaning Remarks
2 Ignition key assignment transmitted by Instrument Cluster Control Module J285
  • Display = "0"
  • The ignition was switched on with a key for which there is no assignment in the Instrument Cluster Control Module J285
  • Display = "1 to 4"
  • The ignition was switched on using the key set in the Instrument Cluster Control Module J285 to position (1, 2, 3 or 4).
  • Data are transmitted via the CAN-Bus comfort system
  • Check adaptation of ignition key "Guided Fault-Finding" Vehicle Diagnosis, Testing Info. System VAS5051B or Vehicle Diagnosis Service Syst. VAS5052 and →
  • Up to 4 keys can be assigned.
NOTE:
  • Ignition key assignment can only be detected and thus transmitted by the Instrument Cluster Control Module J285 on vehicles installed with an immobilizer "Guided Fault-Finding" Vehicle Diagnosis, Testing Info. System VAS5051B or Vehicle Diagnosis Service Syst. VAS5052 and → (Servicing instrument cluster).
  • When the ignition is switched on, the operating and display module, Climatronic Control Module J255 starts with the settings which were valid the last time the ignition was switched off with this key (temperature, air distribution, Fresh Air Blower speed).
  • If the ignition is switched on using a key not released for this vehicle (e.g. via the emergency starting function), the operating and display module, Climatronic Control Module J255 as of hardware/software version "0711" switches automatically to "Off" mode after switching on the ignition and can only be switched to "Def" mode with the ignition switched on (no other settings possible). At the same time, a fault is stored in the operating and display module, Climatronic Control Module J255 (Anti-Theft Immobilizer Control Module J334). This function was incorporated as part of enhancement of the anti-theft protection system.
Display field Meaning Remarks
3 Signal for windshield wiper operating status from Steering Column Electronic Systems Control Module J527
  • Display = "00000"
  • No windshield wiper or wipe/wash operation activated (wipers in rest position)
  • Display = "X0001"
  • Intermittent windshield wiper operation
  • Display = "X0010"
  • Windscreen wiper speed "1" operation
  • Display = "X0100"
  • Windscreen wiper speed "2" operation
  • Display = "X1000"
  • Windscreen wiper wipe/wash mode
  • Display = "10000"
  • Intended for windshield wiper operation via rain sensor (introduction not yet finalized)
  • Data are transmitted via the CAN-Bus comfort system
  • The Steering Column Electronic Systems Control Module J527 transmits the information on the current windshield wiper operating status
NOTE:
  • Depending on the position of the windshield wiper switch, several operating statuses may also be displayed simultaneously (e.g. "01001" for wipe/wash mode and intermittent operation).
  • Depending on version, "1XXXX" may be displayed for vehicles without and with rain sensor with the windshield wipers switched on although it may not be raining (the operating and display module, Climatronic Control Module J255 assumes that it is raining and sets the display to "1XXXX" even though there is no signal from the rain sensor).
  • The operating status information is required to regulate the evaporator outflow temperature and for vehicles with Air Quality Sensor G238.
Display field Meaning Remarks
4 Signal transmitted by Fresh Air Blower Control Module J126 on operating status of Fresh Air Blower in % (duty cycle)  
 
  • Display = 45 to 54 %
  • Fresh Air Blower V2 and Fresh Air Blower Control Module J126 OK
  • No faults present
 
  • Display = "0 to 10 %"
  • No signal from Fresh Air Blower Control Module J126
  • Check for short to Ground (GND) or open circuit in wiring between Fresh Air Blower Control Module J126 and operating and display module, Climatronic Control Module J255
  • Open circuit in power supply to Fresh Air Blower Control Module J126, check
  • Fresh Air Blower Control Module J126 defective, replace Fresh Air Blower V2 with Fresh Air Blower Control Module J126
 
  • Display = "15 to 24 %"
  • Switching relay (for solar operation) in Fresh Air Blower Control Module J126 defective
  • Replace Fresh Air Blower V2 with Fresh Air Blower Control Module J126
 
  • Display = "25 to 34 %"
  • Voltage at Fresh Air Blower Control Module J126 too high
  • Check power supply to Fresh Air Blower Control Module J126
 
  • Display = "35 to 44 %"
  • Voltage at Fresh Air Blower Control Module J126 too low
  • Check and repair voltage supply and Ground (GND) connection to Fresh Air Blower Control Module J126
Display field Meaning Remarks
4
  • Display = "55 to 64 %"
  • Fresh Air Blower V2 stiff or blocked
  • Remove Fresh Air Blower V2 and check for obstruction
  • Replace Fresh Air Blower V2 with Fresh Air Blower Control Module J126
 
  • Display = "65 to 74 %"
  • Fresh Air Blower V2 stiff or blocked
  • Short circuit in Fresh Air Blower Control Module J126 or Fresh Air Blower V2
  • Remove Fresh Air Blower V2 and check for obstruction
  • Replace Fresh Air Blower V2 with Fresh Air Blower Control Module J126
 
  • Display = "75 to 84 %"
  • No activation signal from operating and display module, Climatronic Control Module J255 being applied to Fresh Air Blower Control Module J126 (e.g. air conditioner switched off)
  • Activate activation of Fresh Air Blower V2 at operating and display module, Climatronic Control Module J255
  • Check for open circuit in wiring between Fresh Air Blower Control Module J126 and operating and display module, Climatronic Control Module J255
 
  • Incorrect signal from Fresh Air Blower Control Module J126 (signal frequency outside permissible tolerance)
  • Fresh Air Blower Control Module J126 defective, replace Fresh Air Blower V2 with Fresh Air Blower Control Module J126
 
  • Display = "95 to 100 %"
  • No signal from Fresh Air Blower Control Module J126
  • Check for short to positive in wiring between Fresh Air Blower Control Module J126 and operating and display module, Climatronic Control Module J255
  • Fresh Air Blower Control Module J126 defective, replace Fresh Air Blower V2 with Fresh Air Blower Control Module J126
NOTE:
  • If activation of the Fresh Air Blower is OK and the Fresh Air Blower Control Module J126 does not detect any faults, the current Fresh Air Blower speed is transmitted via a square-wave signal to the operating and display module, Climatronic Control Module J255. With this square-wave signal the duty cycle is approx. 50% and the frequency 1/20 of the Fresh Air Blower speed (example: at a Fresh Air Blower speed of 3000 RPM the frequency of the square-wave signal is 150 Hertz or pulses per second).
  • If a fault is detected by the Fresh Air Blower Control Module J126, the Fresh Air Blower Control Module J126 transmits a square-wave signal with a frequency of 10 Hertz (pulses per second). The operating and display module, Climatronic Control Module J255 recognizes the fault detected via the duty cycle.