Display group "017"
WARNING: This page is about a different car, the 2008 Audi S4, 2008 Audi RS 4, and 2008 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.
Transmitted/measured status, voltage at terminal "15", "75" and "30"
| Display field |
Meaning |
Remarks |
| 1 |
Information transmitted by Steering Column Electronic Systems Control Module J527 to terminal "15"
- Terminal "15" ON information being applied (ignition switched on)
- Terminal "15" ON information not being applied (ignition switched off)
|
- Data are transmitted via the CAN-Bus comfort system
- The Steering Column Electronic Systems Control Module J527 transmits the information "Ignition switched on"
|
| 2 |
Information transmitted by Steering Column Electronic Systems Control Module J527 to terminal "75"
- Terminal "75" ON information being applied (ignition switched on)
- Terminal "75" ON information not being applied (ignition switched off or engine in the process of being started)
|
- Data are transmitted via the CAN-Bus comfort system
- The Steering Column Electronic Systems Control Module J527 transmits the information "Terminal 75 on"
- With the ignition switched on, the terminal "75" ON information must always be applied except on starting the engine.
|
| Display field |
Meaning |
Remarks |
| 3 |
Application of voltage from terminal "75" at operating and display module, Climatronic Control Module J255
- Connector "C", contact "13" supplied with voltage from terminal "75" (ignition switched on)
- Connector "C", contact "13" not supplied with voltage from terminal "75" (ignition switched off or engine in the process of being started)
|
- The voltage is determined via the input from connector "C", contact "13" to the operating and display module, Climatronic Control Module J255
- With the ignition switched on, voltage must always be applied to terminal "75" except on starting the engine.
|
| 4 |
Measured voltage at terminal "30" in V
- Terminal "30" voltage measured at connector "D", contact "12"
|
- The voltage is measured at connector "D" to the operating and display module, Climatronic Control Module J255 between contacts "12" and "13"
|