Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 1499 (Heating & Air Conditioning (On Board Diagnostic)) >> 01 On Board Diagnostic (OBD) >> Read Measuring Value Block (function 08) >> Measuring value blocks from "001" to "010" >> Display group "008"

Display group "008"

WARNING: This page is about a different car, the 2008 Audi S4, 2008 Audi RS 4, and 2008 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.

Recirculation Flap Motor V113 

Display field Meaning Remarks
1 Actual feedback value of Recirculation Flap Motor Position Sensor G143 (in Recirculation Flap Motor V113)
  • Display value greater than "9" and less than "251"
  • Maximum permissible deviation "3" units from specified feedback value (in range greater than "50" but less than "200")
2 Specified feedback value for Recirculation Flap Motor Position Sensor G143 (calculated by operating and display module, Climatronic Control Module J255)
  • Display range "10 to 245"
3 Value determined during "Basic setting" and stored in the operating and display module, Climatronic Control Module J255 for the Recirculation Flap Motor Position Sensor G143 with control motor set to "Lower stop" (recirculated-air flap closed, fresh-air mode)
  • Display value greater than "9" and less than "71"
4 Value determined during "Basic setting" and stored in the operating and display module, Climatronic Control Module J255 for the Recirculation Flap Motor Position Sensor G143 with control motor set to "Upper stop" (recirculated-air flap open, recirculated-air mode)
  • Display value greater than "189" and less than "246"
NOTE:
  • The Recirculation Flap Motor V113 only moves the recirculated-air flap. The air flow/fresh-air flaps are moved by the Air Flow Flap Motor V71.
  • On right-hand drive vehicles, the Recirculation Flap Motor V113 moves both the recirculated-air flap and the fresh-air flaps. As these vehicles are not installed with an Air Flow Flap Motor V71, the fresh-air flaps cannot be used as air flow flaps and air flow mode is thus not possible.
  • The notes on display group "003" also apply to this display group and should be observed if necessary.