Display group "005"
WARNING: This page is about a different car, the 2008 Audi S4, 2008 Audi RS 4, and 2008 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.
Defroster Flap Motor V107
| Display field | Meaning | Remarks |
|---|---|---|
| 1 | Actual feedback value of Defroster Flap Motor Position Sensor G135 (in Defroster Flap Motor V107) |
|
| 2 | Specified feedback value for Defroster Flap Motor Position Sensor G135 (calculated by operating and display module, Climatronic Control Module J255) |
|
| 3 | Value determined during "Basic setting" and stored in the operating and display module, Climatronic Control Module J255 for the Defroster Flap Motor Position Sensor G135 with control motor set to "Lower stop" (defroster flap closed) |
|
| 4 | Value determined during "Basic setting" and stored in the operating and display module, Climatronic Control Module J255 for the Defroster Flap Motor Position Sensor G135 with control motor set to "Upper stop" (defroster flap open) |
|
NOTE:
- At present, the defroster flap is not completely opened even in "Defrost mode". This results in some of the air always being routed to the other vents. The upper specified feedback value displayed is thus "145 to 160".
- The notes on display group "003" also apply to this display group and should be observed if necessary.