Display group "002"
WARNING: This page is about a different car, the 2008 Audi S4, 2008 Audi RS 4, and 2008 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.
Last four compressor shutoff criteria
| Display field | Meaning | Remarks |
|---|---|---|
| 1 | Current, valid compressor shutoff condition |
|
| 2 | Last compressor shutoff condition | |
| 3 | Last but one compressor shutoff condition | |
| 4 | Third last compressor shutoff condition |
NOTE:
- In the event of several simultaneous compressor shutoff criteria (display zone "1"), either the shutoff criteria are displayed alternately or the only shutoff condition displayed is the one given the highest priority by the operating and display module, Climatronic Control Module J255.
- The current compressor shutoff criteria are indicated in display zone "1".
- The only shutoff criteria stored in display zones "2", "3 " and "4" are those marked with a * . They are however only stored if they were active for more than 20 seconds (shutoff condition "12" is already stored after 12 seconds).
- If the compressor is shut off again and display zones "2" to "4 " in this display group do not indicate any compressor shutoff condition, additionally check the display in display groups "026" and "027".
- If, with an operating and display module, Climatronic Control Module J255 up to hardware/software version "0610", compressor shutoff condition "3" (pressure in refrigerant circuit too low) occurs, the operating and display module, Climatronic Control Module J255 switches automatically to "ECON" mode and No fault is stored. This situation is stored as being a malfunction as of hardware/software version "0711".
- In the case of an operating and display module, Climatronic Control Module J255 up to hardware/software version "0610" it may not be possible to erase the compressor shutoff condition stored in display zones "2" to "4".