Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 1499 (Heating & Air Conditioning (On Board Diagnostic)) >> 01 On Board Diagnostic (OBD) >> Automatic Climate Control System, electrical testing >> Test steps "5" to "9" >> Engagement signal for A/C Compressor Regulator Valve N280, checking

Engagement signal for A/C Compressor Regulator Valve N280, checking

WARNING: This page is about a different car, the 2008 Audi S4, 2008 Audi RS 4, and 2008 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Using Adapter From Connector Test Set V.A.G 1594C To Reestablish Connection Between Connector & Connector At Compressor
GW00021280Courtesy of VOLKSWAGEN UNITED STATES, INC.
Fig 2: Identifying Connectors & Sockets For Banana Plugs
GW00021281Courtesy of VOLKSWAGEN UNITED STATES, INC.
NOTE:
  • Use can also be made for this test of an improvised adapter. This requires, for example, one connector - - and - - each (with part number 1J0 973 702 and 1J0 973 802 and the corresponding plug contacts), two commercially available sockets for banana plugs - - and two wires with a cross section of 0.5 mm 2 .

Display on oscilloscope screen will be as follows depending on setting on operating and display module, Climatronic Control Module J255 :

Fig 3: Oscilloscope Screen Display
GW00021282Courtesy of VOLKSWAGEN UNITED STATES, INC.
NOTE:
  • The illustration shows a signal with a ratio of approx. 80%.
  • The pulse width - - is governed by the required cooling output, electrical system voltage etc. (over width of area - -, current is controlled via A/C Compressor Regulator Valve N280 by operating and display module, Climatronic Control Module J255).
  • The signal distance - - is always 2 milliseconds (corresponding to a frequency of 500 Hertz).
  • The duty cycle is derived from the ratio of pulse width - - to signal distance - -.
NOTE:
  • In "Auto" mode with "Lo" temperature setting, the A/C Compressor Regulator Valve N280 is activated such that the max. perm. current of approx. 0.6 to 0.8 A flows via the A/C Compressor Regulator Valve N280 (maximum compressor output).
  • In control mode, the activation time is governed by the required cooling output and vehicle electrical system voltage, for example. It is however always of sufficient duration to achieve a mean current of 0.3 A.