LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 1498 (3.0L - Engine Controls - Generic Scan Tool, Engine Codes: AVK, BGN [Automatic Transmission - Gears, Hydraulic Controls - Generic Scan Tool]) >> Generic Scan Tool >> Diagnostic Trouble Code Tables >> SAE P2xxx Diagnostic Trouble Codes >> Additional emission regulations

Additional emission regulations

WARNING: This page is about a different car, the 2006 Audi A4, 2005 Audi A4, 2004 Audi A4, 2003 Audi A4, and 2002 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.
DTC Error Message Diagnostic Procedure Malfunction Criteria and Threshold Value Secondary Parameters with Enable Conditions Monitoring Time Length Frequency of checks, MIL Illumination
P2400 Evaporative Emission System Leak Detection Pump Control Circuit/Open Open circuit 4.5 5.5 V
  • LDP Commanded On
  • Engine speed >80 RPM
0.5 Sec
  • 2 DCY
P2401 Evaporative Emission System Leak Detection Pump Control Circuit Low Short to ground 3.0 V
  • LDP Commanded - Off
  • Engine speed >80 RPM
  • Battery voltage 9.0 16.05V
0.5 Sec
  • 2 DCY
P2402 Evaporative Emission System Leak Detection Pump Control Circuit High Short to battery+> 3.0 V
  • LDP Commanded On
  • Engine speed >80 RPM
0.5 Sec
  • 2 DCY
P2403 Evaporative Emission System Leak Detection Pump Sense Circuit/Open Contact unable to close, Signal always low
  • LDP Commanded - Off
  • Purge valve check Completed Ref. P0442
0.5 Sec
  • 2 DCY
P2404 Evaporative Emission System Leak Detection Pump Sense Range/Performance Contact unable to open Signal always high
  • LDP Commanded - Off
  • Purge valve check Completed Ref. P0442
0.5 Sec
  • 2 DCY
P2414 O2 Sensor Exhaust Sample Error (Bank 1 Sensor 1)
  • (BGN only)
Signal voltage, 3.7-4.8 V
  • O2S ceramic temp. 750+/-65°C
  • If low fuel signal then wait >600 Sec.
  • SAI - not active
10 Sec
  • Continuous
  • 2 DCY
P2415 O2 Sensor Exhaust Sample Error (Bank 2 Sensor 1)
  • (BGN only)
Signal voltage, 3.7-4.8 V
  • O2S ceramic temp. 750+/-65°C
  • If low fuel signal then wait >600 Sec.
  • SAI - not active
10 Sec
  • Continuous
  • 2 DCY
P2626 O2 Sensor Pumping Current Trim Circuit/Open (Bank 1 Sensor 1)
  • (BGN only)
O2S signal front, > 4.8 V
  • O2S ceramic temp 750 +/- 65°C
  • Modeled exhaust gas temp - 700°C
  • Fuel cut off Active
  • If low fuel signal on, wait>600 Sec.
20 Sec
  • Continuous
  • 2 DCY
P2629 O2 Sensor Pumping Current Trim Circuit/Open (Bank 2 Sensor 1)
  • (BGN only)
O2S signal front,> 4.8 V
  • O2S ceramic temp 750 +/- 65°C
  • Modeled exhaust gas temp - 700°C
  • Fuel cut off Active
  • If low fuel signal on, wait>600 Sec.
20 Sec
  • Continuous
  • 2 DCY