| DTC | Error Message | Diagnostic Procedure | Malfunction Criteria and Threshold Value | Secondary Parameters with Enable Conditions | Monitoring Time Length | Frequency of checks, MIL Illumination |
|---|---|---|---|---|---|---|
| P0010 | Intake (A) Camshaft Position Actuator Circuit/Open (Bank 1) |
|
|
|
0.5 Sec |
|
| P0011 | Intake (A) Camshaft Position Timing - Over-Advanced (Bank 1) |
|
|
|
40 Sec |
|
| P0012 | Intake (A) Camshaft Position Timing Over-Retarded (Bank 1) AVK Only. |
|
|
|
40 Sec |
|
| P0013 | "B" Camshaft Position - Actuator Circuit Bank 1 |
|
|
|
0.5 Sec |
|
| P0014 | "B" Camshaft Position - Timing Over-Advanced or System Performance Bank 1 |
|
|
|
30 Sec |
|
| P0015 | "B" Camshaft Position - Timing Over Retarded (Bank 1) |
|
|
|
|
|
| P0020 | Intake (A) Camshaft Position Actuator Circuit/Open (Bank 2) |
|
|
|
|
|
| P0021 | Intake (A) Camshaft Position Timing Over-Advanced (Bank 2) |
|
|
|
|
|
| P0022 | Intake (A) Camshaft Position Timing Over-Retarded (Bank 2)
|
|
|
|
|
|
| P0023 | "B" Camshaft Position - Actuator Circuit (Bank 2) |
|
|
|
|
|
| P0024 | "B" Camshaft Position - Timing Over-Advanced or System Performance (Bank 2) |
|
|
|
|
|
| P0025 | "B" Camshaft Position - Timing Over-Retarded (Bank 2) |
|
|
|
|
|
| P0030 | HO2S Heater Control Circuit (Bank 1, Sensor 1) |
|
|
|
5 Sec |
|
| P0031 | HO2S Heater Control Circuit Low (Bank 1, Sensor 1) |
|
Short to ground - 2.34 V |
|
5 Sec |
|
| P0032 | HO2S Heater Control Circuit High (Bank 1, Sensor 1) |
|
Short to battery + >3.59 V |
|
5 Sec |
|
| P0036 | HO2S Heater Control Circuit (Bank 1, Sensor 2) |
|
Open circuit 4.5-5.5 V |
|
5 Sec |
|
| P0037 | HO2S Heater Control Circuit Low (Bank 1, Sensor 2) |
|
Short to ground 3 V |
|
5 Sec |
|
| P0038 | HO2S Heater Control Circuit High (Bank 1, Sensor 2) |
|
Short to battery + >2.7-5.5 A |
|
5 Sec |
|
| P0050 | HO2S Heater Control Circuit Bank 2 Sensor 1 |
|
Open circuit 2.34-3.59 V |
|
5 Sec |
|
| P0051 | HO2S Heater Control Circuit Low Bank 2 Sensor 1 |
|
Short to ground - 2.34 V |
|
5 Sec |
|
| P0052 | HO2S Heater Control Circuit High Bank 2 Sensor 1 |
|
Short to battery + >3.59 V |
|
5 Sec |
|
| P0056 | HO2S Heater Control Circuit Bank 2 Sensor 2 |
|
Open circuit 4.5-5.5 V |
|
5 Sec |
|
| P0057 | HO2S Heater Control Circuit Low Bank 2 Sensor 2 |
|
Short to ground 3 V |
|
5 Sec |
|
| P0058 | HO2S Heater Control Circuit High Bank 2 Sensor 2 |
|
Short to battery + >2.7-5.5 A |
|
5 Sec |
|