Abnormality Judgment
Judge as NG (large leakage) when the following conditions are established.
| Malfunction Criteria | Threshold Value | DTC |
|---|---|---|
| Time to reach target negative pressure or |
≥ 10000 ms+ 25000 ms | P0457 |
| Mode B time | ≥ 10000 ms | |
| (Min. pressure value in tank when in mode B) - (Tank pressure when mode B started) | > -0.3 kPa (-2.5 mmHg, -0.1 inHg) |
Time Needed for Diagnosis: 0 ms + 3000 ms + 10000 ms + 10000 ms + 25000 ms
Mode C: (Check pressure rise)
Stop the introduction of negative pressure. (Wait until the tank pressure returns to the start level of P2 calculation.)
Change to Mode D when the tank pressure returns to the start level of P2 calculation.
Judge advanced OK and change to Mode E when it does not return in spite of spending the specified time.
| Tank pressure when starting calculation of P2 | Time for advanced OK judgment |
|---|---|
| -1.4 kPa (-10.5 mmHg, -0.4 inHg) | 18600 ms |
Time Needed for Diagnosis: 0 ms + 3000 ms + 10000 ms + 10000 ms + 25000 ms + 18600 ms
Mode D: (Measure amount of negative pressure change)
Monitor the tank pressure change amount when using mode D. In this case, the tank pressure increases, (nears barometric pressure) because evaporation occurs. However, if any leakage exists, the pressure increases additionally in proportion to this leakage. The pressure variation of this tank is P2. After calculating P2, perform a small leak diagnosis according to the items below.
When Mode D is ended
Assign tank variations measured in Mode A and Mode D, P1 and P2, to the formula below, judge small leaks in the system. If the measured judgment value exceeds the threshold value, it is judged to be a malfunction.
Judge as NG when the following conditions are established within the predetermined time. Judge as OK and clear the NG if the following conditions are not established within the predetermined time.
| Malfunction Criteria | Threshold Value | DTC |
|---|---|---|
| P2 - 1.5 - x P1 P2: Tank pressure that changes every 10000 ms in mode D P1: Tank pressure that changes every 10000 ms in mode A |
> Value of Map 5 | P0442 |
| *1.5 -: Evaporation amount compensation value when below negative pressure (Amount of evaporation occurrence increases as a vacuum condition increases.) | ||
| Fuel temperature vs. Fuel level | 25 °C (77°F) | 30 °C (86°F) | 35 °C (95°F) | 40°C (104°F) | 45°C (113°F) |
| 0 l (0 US gal, 0 lmp gal) | 0.3 kPa (2.1 mmHg, 0.1 inHg) | 0.3 kPa (2.2 mmHg, 0.1 inHg) | 0.3 kPa (2.3 mmHg, 0.1 inHg) | 0.3 kPa (2.35 mmHg, 0.1 inHg) | 0.3 kPa (2.4 mmHg, 0.1 inHg) |
| 10 l (2.64 US gal, 2.2 lmp gal) | 0.3 kPa (2.1 mmHg, 0.1 inHg) | 0.3 kPa (2.2 mmHg, 0.1 inHg) | 0.3 kPa (2.3 mmHg, 0.1 inHg) | 0.3 kPa (2.35 mmHg, 0.1 inHg) | 0.3 kPa (2.4 mmHg, 0.1 inHg) |
| 20 l (5.28 US gal, 4.4 lmp gal) | 0.3 kPa (2.3 mmHg, 0.1 inHg) | 0.3 kPa (2.4 mmHg, 0.1 inHg) | 0.3 kPa (2.5 mmHg, 0.1 inHg) | 0.3 kPa (2.6 mmHg, 0.1 inHg) | 0.4 kPa (2.7 mmHg, 0.1 inHg) |
| 30 l (7.93 US gal, 6.6 lmp gal) | 0.4 kPa (2.9 mmHg, 0.1 inHg) | 0.4 kPa (3.05 mmHg, 0.1 inHg) | 0.4 kPa (3.15 mmHg, 0.1 inHg) | 0.4 kPa (3.25 mmHg, 0.1 inHg) | 0.4 kPa (3.35 mmHg, 0.1 inHg) |
| 40 l (10.57 US gal, 8.8 lmp gal) | 0.4 kPa (2.9 mmHg, 0.1 inHg) | 0.4 kPa (3.15 mmHg, 0.1 inHg) | 0.4 kPa (3.3 mmHg, 0.1 inHg) | 0.5 kPa (3.4 mmHg, 0.1 inHg) | 0.5 kPa (3.5 mmHg, 0.1 inHg) |
| 50 l (13.21 US gal, 11 lmp gal) | 0.4 kPa (3.2 mmHg, 0.1 inHg) | 0.4 kPa (3.3 mmHg, 0.1 inHg) | 0.5 kPa (3.5 mmHg, 0.1 inHg) | 0.5 kPa (3.6 mmHg, 0.1 inHg) | 0.5 kPa (3.7 mmHg, 0.1 inHg) |
| 60 l (15.85 US gal, 13.2 lmp gal) | 0.4 kPa (3.2 mmHg, 0.1 inHg) | 0.4 kPa (3.3 mmHg, 0.1 inHg) | 0.5 kPa (3.5 mmHg, 0.1 inHg) | 0.5 kPa (3.6 mmHg, 0.1 inHg) | 0.5 kPa (3.7 mmHg, 0.1 inHg) |