LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 131 (Diagnostic Trouble Code (DTC) Detecting Criteria (H4DOTC)) >> Diagnostic Trouble Code (DTC) Detecting Criteria >> DTC P0442 Evaporative Emission Control System Leak Detected (Small Leak) >> Diagnostic Method >> Abnormality Judgment

Abnormality Judgment

WARNING: This page is about a different car, the 2012 Subaru Forester. However, it is still accessible from the selected car via links, so may be relevant.

Judge as NG (large leakage) when the following conditions are established.

JUDGMENT VALUE REFERENCE CHART

Malfunction Criteria Threshold Value DTC
Time to reach target negative pressure
or
≥ 10000 ms+ 25000 ms P0457
Mode B time ≥ 10000 ms  
(Min. pressure value in tank when in mode B) - (Tank pressure when mode B started) > -0.3 kPa (-2.5 mmHg, -0.1 inHg)  

Time Needed for Diagnosis:  0 ms + 3000 ms + 10000 ms + 10000 ms + 25000 ms

Mode C: (Check pressure rise) 

Stop the introduction of negative pressure. (Wait until the tank pressure returns to the start level of P2 calculation.)

Change to Mode D when the tank pressure returns to the start level of P2 calculation.

Judge advanced OK and change to Mode E when it does not return in spite of spending the specified time.

AIR PRESSURE REFERENCE CHART

Tank pressure when starting calculation of P2 Time for advanced OK judgment
-1.4 kPa (-10.5 mmHg, -0.4 inHg) 18600 ms

Time Needed for Diagnosis:  0 ms + 3000 ms + 10000 ms + 10000 ms + 25000 ms + 18600 ms

Mode D: (Measure amount of negative pressure change) 

Monitor the tank pressure change amount when using mode D. In this case, the tank pressure increases, (nears barometric pressure) because evaporation occurs. However, if any leakage exists, the pressure increases additionally in proportion to this leakage. The pressure variation of this tank is P2. After calculating P2, perform a small leak diagnosis according to the items below.

When Mode D is ended 

Assign tank variations measured in Mode A and Mode D, P1 and P2, to the formula below, judge small leaks in the system. If the measured judgment value exceeds the threshold value, it is judged to be a malfunction.



Judge as NG when the following conditions are established within the predetermined time. Judge as OK and clear the NG if the following conditions are not established within the predetermined time.

JUDGMENT VALUE REFERENCE CHART

Malfunction Criteria Threshold Value DTC
P2 - 1.5 - x P1
P2: Tank pressure that changes every 10000 ms in mode D
P1: Tank pressure that changes every 10000 ms in mode A
> Value of Map 5 P0442
*1.5 -: Evaporation amount compensation value when below negative pressure (Amount of evaporation occurrence increases as a vacuum condition increases.)
FUEL TEMPERATURE RESISTANCE REFERENCE CHART

Fuel temperature vs. Fuel level 25 °C (77°F) 30 °C (86°F) 35 °C (95°F) 40°C (104°F) 45°C (113°F)
0 (0 US gal, 0 lmp gal) 0.3 kPa (2.1 mmHg, 0.1 inHg) 0.3 kPa (2.2 mmHg, 0.1 inHg) 0.3 kPa (2.3 mmHg, 0.1 inHg) 0.3 kPa (2.35 mmHg, 0.1 inHg) 0.3 kPa (2.4 mmHg, 0.1 inHg)
10 (2.64 US gal, 2.2 lmp gal) 0.3 kPa (2.1 mmHg, 0.1 inHg) 0.3 kPa (2.2 mmHg, 0.1 inHg) 0.3 kPa (2.3 mmHg, 0.1 inHg) 0.3 kPa (2.35 mmHg, 0.1 inHg) 0.3 kPa (2.4 mmHg, 0.1 inHg)
20 (5.28 US gal, 4.4 lmp gal) 0.3 kPa (2.3 mmHg, 0.1 inHg) 0.3 kPa (2.4 mmHg, 0.1 inHg) 0.3 kPa (2.5 mmHg, 0.1 inHg) 0.3 kPa (2.6 mmHg, 0.1 inHg) 0.4 kPa (2.7 mmHg, 0.1 inHg)
30 (7.93 US gal, 6.6 lmp gal) 0.4 kPa (2.9 mmHg, 0.1 inHg) 0.4 kPa (3.05 mmHg, 0.1 inHg) 0.4 kPa (3.15 mmHg, 0.1 inHg) 0.4 kPa (3.25 mmHg, 0.1 inHg) 0.4 kPa (3.35 mmHg, 0.1 inHg)
40 (10.57 US gal, 8.8 lmp gal) 0.4 kPa (2.9 mmHg, 0.1 inHg) 0.4 kPa (3.15 mmHg, 0.1 inHg) 0.4 kPa (3.3 mmHg, 0.1 inHg) 0.5 kPa (3.4 mmHg, 0.1 inHg) 0.5 kPa (3.5 mmHg, 0.1 inHg)
50 (13.21 US gal, 11 lmp gal) 0.4 kPa (3.2 mmHg, 0.1 inHg) 0.4 kPa (3.3 mmHg, 0.1 inHg) 0.5 kPa (3.5 mmHg, 0.1 inHg) 0.5 kPa (3.6 mmHg, 0.1 inHg) 0.5 kPa (3.7 mmHg, 0.1 inHg)
60 (15.85 US gal, 13.2 lmp gal) 0.4 kPa (3.2 mmHg, 0.1 inHg) 0.4 kPa (3.3 mmHg, 0.1 inHg) 0.5 kPa (3.5 mmHg, 0.1 inHg) 0.5 kPa (3.6 mmHg, 0.1 inHg) 0.5 kPa (3.7 mmHg, 0.1 inHg)