LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 1274 (General, Technical Data (Refrigerant R134A Servicing)) >> 00 General, Technical Data >> Refrigerant Circuit, Detecting Leaks >> Refrigerant Circuit, Tracing Leaks, With Leak Detection System :Vas6196 Or Leak Detection Kit :Vas6201A Or Succeeding Model >> Refrigerant Circuit, Detecting Leaks Using UV Lamp Vas6196/4

Refrigerant Circuit, Detecting Leaks Using UV Lamp Vas6196/4

WARNING: This page is about a different car, the 2014 Volkswagen Touareg, 2013 Volkswagen Touareg, 2012 Volkswagen Touareg, and 2011 Volkswagen Touareg. However, it is still accessible from the selected car via links, so may be relevant.
CAUTION:

- Wear protective eyewear.

- Never look into the UV lamp.

- Never point the UV lamp at another person.

NOTE:

The A/C system must run for at least 60 minutes so the additive distributes itself through the entire refrigerant circuit. The compressor must be running. Depending on the size of the leak, it may become visible within that time.

With leaks on evaporator, leak detection additive is possibly washed off with condensation and flows out via evaporator drain. Since the evaporator is not easily accessible on most vehicles, checking the evaporator drain may indicate if the evaporator is leaking. However, it is necessary for this purpose that leak detection additive has already been in the refrigerant circuit for a long period of time.

Protective eyewear not only serves as eye protection, but also amplifies the illumination of leak detection additive under UV light.

Depending on the accessibility of different components in the refrigerant circuit, it may be necessary to remove some vehicle components such as the bumper or air filter.

-- Move vehicle into a slightly darker area of the workshop (with daylight or bright lighting the effect of the UV light is diminished).

GWWA87-0492Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

-- Check the accessibility of the various components in the refrigerant circuit and remove any components in the area that block access to the refrigerant circuit such as noise insulation and the bumper.

-- Wear protective eyewear to protect the eyes.

-- Connect the UV-lamp to a 12 volt battery (vehicle battery). Observe the correct polarity of connections.

-- Switch on the UV lamp and illuminate the components of refrigerant circuit. Locations where refrigerant, refrigerant oil and leak detection additive has leaked out light up under fluorescent UV light.

NOTE:

The leak detection additive can remain in the refrigerant circuit.

Remove existing leak detection additive in the engine compartment or from the refrigerant circuit components using Leak Detection Kit - Cleaning Solution -VAS6201/3-.