Refrigerant Circuit, Tracing Leaks, With Leak Detection System :Vas6196 Or Leak Detection Kit :Vas6201A Or Succeeding Model: Notes
Small leaks can be detected using a UV-leak detection additive for example.
-- Evacuate the refrigerant circuit with the A/C Service Station. Refer to REFRIGERANT CIRCUIT, EVACUATING WITH A/C Service Station .
Be ready to evacuate a large leak should one be found. Refer to REFRIGERANT CIRCUIT, EVACUATING WITH A/C Service Station .
If no leak is found during evacuation or there is a leak that is so small that the location cannot be found, proceed as follows. Refer to SEARCHING FOR REFRIGERANT CIRCUIT LEAKS WITH COMPRESSED AIR OR NITROGEN .
Currents of air quickly disperse refrigerant gas. Drafts must therefore be avoided during leak detection.
If the refrigerant circuit is completely empty, fill with refrigerant to approximately 10% of the fill capacity (R134a label or vehicle-specific Service Information).
Leak Detection SystemVAS6196
or
Leak Detection SystemVAS6201 or Succeeding Model
- Leak Detection Kit - Hand Pump w/Cartridge -VAS6201/1-
- Leak Detection Kit - Cartridge -VAS6201/2-
- Leak Detection Kit - Cleaning Solution -VAS6201/3-
- UV Leak Detection Lamp -VAS6201/4A-
- Leak Detection Kit - Eye Protection -VAS6201/6-
- Leak Detection Kit - Sticker -VAS6201/7-
- Leak Detection Kit - Filler Tube -- VAS6201/8
- Leak Detection Kit - Hand Protection -VAS6201/9-