A/C Pressure/Temperature Sensor -G395-
Danger or frostbite due to refrigerant coming out under pressure.
Frostbite on the skin and other parts of the body is possible.
- Wear safety gloves.
- Wear protective eyewear.
- Extract refrigerant and open the refrigerant circuit immediately.
- If more than 10 minutes elapse after extracting the refrigerant and the refrigerant circuit was not opened, extract the refrigerant again. Evaporation can cause pressure to develop in the refrigerant circuit.
For switching pressures, removing and installing switches and switch arrangement and version, see vehicle-specific refrigerant circuit.
Refer to the appropriate service information .
This A/C Pressure/Temperature Sensor -G395- is installed instead of the High Pressure Sensor -G65- or A/C Pressure Switch -F129-.
The pressure signal is always being checked, where the temperature signal is only checked at temperatures above 0 °C (32 °F).
The Climatronic Control Module -J255- operates with this information and controls the coolant fans and activation of the A/C Compressor Regulator Valve -N280-.