Evacuating And Charging Valve With SCHRADER Valve
Special Tools And Workshop Equipment Required
- Torque Wrench 1783 - 2-10Nm:VAG1783 with Torque Wrench 1783 - 1/4" Drive Ratchet:VAS6234
Danger or frostbite due to refrigerant coming out under pressure.
Frostbite on the skin and other parts of the body is possible.
- Wear safety gloves.
- Wear protective eyewear.
- Extract refrigerant and open the refrigerant circuit immediately.
- If more than 10 minutes elapse after extracting the refrigerant and the refrigerant circuit was not opened, extract the refrigerant again. Evaporation can cause pressure to develop in the refrigerant circuit.
- Only valves and connections that are resistant to refrigerant R134a and refrigerant oil must be installed.
- Different connections (outer diameter) for high pressure and low pressure side.
- Always screw on sealing caps.
Torque Wrench 1783 - 2-10 Nm :VAG1783 with Torque Wrench 1783 - 1/4" Drive Ratchet:VAS6234
Use a suitable Refrigerant Sockets:T10364 to loosen the Schrader valve insert. Refer to Refrigerant SocketsT10364 for the High Pressure/Low Pressure Side Service Connection Valves in the Refrigerant Circuit .
A - Service connection (soldered in)
B - Schrader valve insert (2.4 ± 0.2 Nm )
C - O-ring (belongs to the valve)
D - Sealing cap with seal