Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 127 (Diagnostic Trouble Code (DTC) Detecting Criteria (H4DO)) >> Diagnostic Trouble Code (DTC) Detecting Criteria >> DTC P0455 Evaporative Emission System Leak Detected (Large Leak) >> Diagnostic Method >> Mode E (Measurement of reference pressure for judgement)

Mode E (Measurement of reference pressure for judgement)

WARNING: This page is about a different car, the 2012 Subaru Forester. However, it is still accessible from the selected car via links, so may be relevant.
  1. Purpose: Judge the reference pressure stability.

    Judge as NG when the following conditions are established.

    JUDGMENT VALUE REFERENCE CHART

    Malfunction Criteria Threshold Value DTC
    Elapsed time after mode change ≥ 40s P2404
    |Pressure sensor maximum output value - Pressure sensor minimum output value| > 0.3 kPa (2.355 mmHg, 0.1 inHg)
  2. Purpose: Judge whether the reference pressure is within the normal range, and detect the vacuum pump and orifice malfunctions. Judge the vacuum pump performance stability.

    Judge as NG when the following conditions are established.

    JUDGMENT VALUE REFERENCE CHART

    Malfunction Criteria Threshold Value DTC
    When any one of the followings is established.   P2404
    • Reference pressure for judgement
    < Value of Map 5
    or
    > Value of Map 6
     
    • |Reference pressure for setting the target negative pressure - Reference pressure for judgement|
    > 0.9 kPa (7.058 mmHg, 0.3 inHg)  
    PRESSURE SPECIFICATION CHART

    Atmospheric pressure kPa (mmHg, inHg) 70 (525, 20.7) 80 (600, 23.6) 90 (675, 26.6) 100 (750, 29.5)
    Reference pressure for judgement kPa (mmHg, inHg) -4.5 (-34.02,-1.3) -4.6 (-34.815,-1.4) -4.7 (-35.618, -1.4) -4.9 (-36.42,-1.4)
    PRESSURE SPECIFICATION CHART

    Atmospheric pressure kPa (mmHg, inHg) 70 (525, 20.7) 80 (600, 23.6) 90 (675, 26.6) 100 (750, 29.5)
    Reference pressure for judgement kPa (mmHg, inHg) -0.8 (-6.18,-0.2) -0.9 (-6.983, -0.3) -1 (-7.785, -0.3) -1.1 (-8.58,-0.3)
  3. Purpose: Judge the presence of evaporative emission system leak.

    Judge as NG when the following conditions are established.

JUDGMENT VALUE REFERENCE CHART

Malfunction Criteria Threshold Value DTC
< Large leak (0.04 inch) >   P0455
Leak pressure > Reference pressure for judgement and  
lleakjdg = (Reference pressure for judgement) x 0.377 -(-0.341) ≥ lleakjdg  
< Very small leak (0.02 inch) >   P0456
Leak pressure > Reference pressure for judgement and < lleakjdg  

Time Needed for Diagnosis:  Approx. 23 min

JUDGMENT VALUE REFERENCE CHART

Malfunction Criteria Threshold Value DTC
NG flag Not set P0455
P0456
P1451
P2404