Leak Detection Pump -V144-, CHECKING VACUUM SUPPLY
Special tools and workshop equipment required
- Turbocharger Tester Kit:VAG1397A
- T-Connection: 251 201 346
- 6 mm hose
Leak Detection Pump -V144- installed location: inside the right rear wheel housing under the wheel housing liner.
-- Remove the right rear wheel and wheel housing liner.
-- Remove the vacuum line -1- from the Leak Detection Pump -V144-
-- Connect the :VAG1397A with the T-piece and 6 mm hose between the vacuum line -1- and the Leak Detection Pump -V144- -2-.
-- Switch on the measuring range I (absolute pressure measurement).
-- Connect the Vehicle Diagnostic Tester and start the engine.
-- Select Guided Functions
-- Select "Check tank ventilation system for leaks".
-- Start the test.
-- During the test, pay attention to the display on the :VAG1397A .
- The pressure must pulsate and must not rise above 0.700 bar (10.15 psi) (absolute pressure) during the test.
-- If the pressure rises above 0.700 bar during the test, the vacuum supply is too low. Check vacuum line to intake manifold for kinks or blockages.