LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 1221 (Exterior Lights, Switches) >> 94 Exterior Lights, Switches >> Peripheral Camera System >> Area View Camera System, Calibrating >> Peripheral Camera Calibration Device :Vas6350/6, Aligning

Peripheral Camera Calibration Device :Vas6350/6, Aligning

WARNING: This page is about a different car, the 2014 Volkswagen Touareg, 2013 Volkswagen Touareg, 2012 Volkswagen Touareg, and 2011 Volkswagen Touareg. However, it is still accessible from the selected car via links, so may be relevant.

Special Tools And Workshop Equipment Required 

The Peripheral Camera Calibration Device :VAS6350/6  is comprise of the following individual parts:

-- Install the : VAS6350/6  .

NOTE:

The :VAS6350/6-1  and the :VAS6350/6-2  must be vertical.

Line up the plates so that the air bubble in the level is exactly in the center of the indicator -arrow-.

GWWN94-10686Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

-- Set the :VAS6350/6-1  -1- and the :VAS6350/6-2  -2- to dimension -B- 77.5 on both sides of the scale on the calibration device.

GWWN94-12018Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

-- Adjust the height of the :VAS6350/6-1  -1- and the :VAS6350/6-2  -2- so that dimension -A- is 150 mm between the lower edge of the black measuring field (not of the aluminum frame) and the surface of the calibration device.

NOTE:

The corners on the outside of the calibration device base plate must always be flush with the outer edge of the black line on the measuring field when performing distance measuring.