LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 1010 (Climate Control System (Precautions & Technical Data - Refrigerant R1234YF)) >> 00 General, Technical Data >> Technical And Physical Principles >> A/C Technology Basic Principles >> Refrigerant Pressure And Boiling Point >> Refrigerant R1234yf vapor pressure

Refrigerant R1234yf vapor pressure

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2018 Audi S6, 2018 Audi A6 Quattro, 2018 Audi A6, 2017 Audi S6, and 2017 Audi A6 Quattro. However, it is still accessible from the selected car via links, so may be relevant.
GWWN87-0530Courtesy of AUDI OF AMERICA, LLC

A - Liquid

B - Gaseous

D - Refrigerant R1234yf vapor pressure

1 - Pressure acting on liquid in bar (absolute)

2 - Temperature in °C

NOTE:

The vapor pressure curves of both refrigerant R1234yf and R134a is similar across a large temperature range. The pressure difference between both refrigerants in the temperature range of 0 to 50 °C (32 to 122 °F) if for example only approximately 0.2 bar (3 psi) for this reason distinguishing the two refrigerants is not possible. Refer to REFRIGERANT VAPOR PRESSURE TABLE  and A/C SYSTEM, GENERAL INFORMATION . Distinguishing is only possible by suitable sensors which can analyze the chemical characteristics of the refrigerant. Refer to REFRIGERANT R1234YF ANALYSIS .