Control module and output signals
WARNING: This page is about a different car, the 2006 Audi A4, 2005 Audi A4, 2004 Audi A4, 2003 Audi A4, and 2002 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.
| DTC | Error Message | Diagnostic Procedure | Malfunction Criteria and Threshold Value | Secondary Parameters with Enable Conditions | Monitoring Time Length | Frequency of checks, MIL Illum |
|---|---|---|---|---|---|---|
| P0600 | Serial Communication Link |
|
Short to battery positive Short to ground Core connection ECM receiving no signal from CAN bus | --- | 0.5 Sec 0.5 Sec | 2 DCY |
| P0601 | Internal Control Module Memory Check Sum Error |
|
Calculate check sum | 0.5 Sec |
|
|
| P0602 | Control Module Programming Error |
|
Message arriving from automatic transmission while ECU is calibrated for manual transmission-Message from automatic transmission | --- | 0.5 Sec | 2 DCY |
| P0603 | Internal Control Module Memory Check Sum Error |
|
Write and read back value is not correct | --- | 200 mS | yes; immediate |
| P0604 | Internal Control Module Random Access Memory (RAM) Error |
|
Write ability check | 0.5 Sec |
|
|
| P0605 | Internal Control Module Read Only Memory (ROM) Error |
|
Wrong check sum | 0.5 Sec |
|
|
| P0606 | Internal Control Module Memory Check Sum Error |
|
Short to Battery +, > 4.88 V Short to Ground, 0.14 V | --- | 2 Sec |
|
| P0638 | Throttle Actuator Control Range/Performance |
|
OPEN to > ref. Point (+) 12%- t> 0.14 seconds Then CLOSED to ref. point (+) 3% t > 0.56 Sec Closed to 1% t > 0.3 Sec then OPEN to ref. (-) 1.5% t > 0.56 Sec Voltage ranges- sensor1: 0.21 - 0.87 V sensor 2: 4.14 - 4.84 V | Ignition-ON Engine speed-0 Rpm Intake air temperature-> 5°C Vehicle speed-0 Mph ECT-> 5°C Ignition-ON Engine speed-0 Rpm Intake air temperature-> 5°C Vehicle speed-0 Mph ECT-> 5°C Ignition-ON Engine speed-0 Rpm Intake air temperature-> 5°C Vehicle speed-0 Mph ECT-> 5°C | 5 Sec |
|
| P0685 | ECM/PCM Power Relay Control CircuitOpen |
|
Open circuit-Control voltage 0.61 Volts | Sense circuit voltage-3.0 Volts | 0.5 Sec |
|
| P0686 | ECM/PCM Power Relay Control Circuit Low |
|
Short to ground-Control voltage 0.51 Volts | Sense circuit voltage- > 5.5 V | 0.5 Sec |
|
| P0687 | ECM/PCM Power Relay Control Circuit High |
|
Short to battery positive-Control voltage >4.0 Volts | Sense circuit voltage- 3.0 V | 0.5 Sec |
|
| P0688 | ECM/PCM Power Relay Sense Circuit Open |
|
Voltage too low-3.0 Volts |
|
2 Sec |
|