LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 10 (1.8L - Turbo Engine Controls - Generic Scan Tool, Engine Code(S): AMB) >> 21 - Turbocharger, G-Charger >> Turbocharger >> Wastegate Bypass Regulator Valve N75 , checking

Wastegate Bypass Regulator Valve N75 , checking

WARNING: This page is about a different car, the 2006 Audi A4, 2005 Audi A4, 2004 Audi A4, 2003 Audi A4, and 2002 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.

Special tools, testers and auxiliary items required 

Test requirements 

Fig 1: Identifying Main Fuse Panel
GW00018580Courtesy of VOLKSWAGEN UNITED STATES, INC.

Procedure 

Fig 2: Removing Engine Cover
GW00017273Courtesy of VOLKSWAGEN UNITED STATES, INC.

Checking internal resistance 

Fig 3: Disconnecting Electrical Harness Connector
GW00015800Courtesy of VOLKSWAGEN UNITED STATES, INC.
Fig 4: Checking Wastegate Bypass Regulator Valve N75 Terminals 1 To 2 For Resistance
GW00015447Courtesy of VOLKSWAGEN UNITED STATES, INC.

Specified value: 20 to 30 Ω (at approx. 20°C)

If the specification was not obtained:

If the specification is obtained:

Checking Voltage supply 

Fig 5: Identifying 2-Pin Electrical Harness Connector & Terminals
GW00001018Courtesy of VOLKSWAGEN UNITED STATES, INC.
Wastegate Bypass Regulator Valve N75 electrical harness connector terminal Measure to
1 Engine Ground (GND)

Specified value: battery voltage.

If the specification was not obtained:

If no malfunction is found in the wiring:

If the manufacturers test box is being used. Perform the following step.

If the manufacturers test box is not being used. Perform the following step.

Fig 6: Identifying 2-Pin Electrical Harness Connector & Terminals
GW00001018Courtesy of VOLKSWAGEN UNITED STATES, INC.
Wastegate Bypass Regulator Valve. N75 electrical harness connector terminal Motronic Engine Control Module (ECM) J220 electrical connector test box socket
2 104

Specified value: 1.5 Ω max.

If the specification is not obtained:

If no malfunction is detected in the wiring and if the voltage supply was OK:

Final procedures 

After the repair work, the following work steps must be performed in the following sequence:

  1. Check the DTC memory.
  2. If necessary, erase the DTC memory. Refer to Diagnostic Mode 04: Reset/delete diagnostic data .
  3. If the DTC memory was erased, generate readiness code. Refer to Readiness Code .