Home >> Audi >> 2016 >> S4 Premium Plus, Standard Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 613 (3.0L - Turbocharger & Supercharger - Engine Code(S): CPNB) >> 21 Turbocharger, Supercharger >> Turbocharger >> Turbocharger Vacuum Diaphragm, Checking >> Low Pressure Turbocharger Vacuum Diaphragm, Adjusting, Vehicles With Engine Code CGQB

Low Pressure Turbocharger Vacuum Diaphragm, Adjusting, Vehicles With Engine Code CGQB

WARNING: This page is about a different car, the 2016 Audi Q5, 2015 Audi Q5, and 2014 Audi Q5. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:

The adjustment only applies to a new vacuum diaphragm.

Fig 1: Special Tools And Workshop Equipment
GWWG21-10001Courtesy of AUDI OF AMERICA, LLC

Special tools and workshop equipment required 

Procedure 

-- Remove the engine cover, refer to ENGINE COVER, REMOVING AND INSTALLING .

-- Secure the Dial Gauge Holder VW387 with the catalytic converter nut -arrow-.

Fig 2: Low Pressure-Vacuum Diaphragm Adjusting
GWWA21-10661Courtesy of AUDI OF AMERICA, LLC

-- Secure the Dial Gauge Set - Dial Gauge VAS6341/1 with a Dial Gauge Set - Flat Pickup VAS6341/4 on the Dial Gauge Holder VW387.

-- Align the dial gauge with the vacuum diaphragm actuator rod.

-- Adjust the dial gauge 20 to 25 mm pretension.

-- Hand Vacuum Pump VAS6213 and Pressure Control Valve VAS6342 to the vacuum diaphragm -arrow- and to connection "II" on the turbocharger tester VAG1397A, as illustrated.

Fig 3: Vacuum Pump Setup
GWWA21-10662Courtesy of AUDI OF AMERICA, LLC

-- Connect the Pressure Control Valve VAS6342.

-- Set the Vacuum Pump VAS6213 slide ring in the "vacuum" position.

-- Switch the Turbocharger Tester Kit VAG1397A and set the slide switch to position "II".

-- Check dial gauge for ease of movement.

-- Operate the Hand Vacuum Pump VAS6213 until the Turbocharger Tester VAG1397A shows the following value:

NOTE:

The Turbocharger Tester Kit VAG1397A cannot display values over 580 mbar.

-- Set dial gauge to "0".

-- Note the measured value.

-- Lower the vacuum via the Pressure Control Valve VAS6342.

NOTE:

If the vacuum was reduced too much, raise the vacuum back to 580 mbar and adjust again by reducing it.

-- Lower the vacuum via the Pressure Control Valve VAS6342.

-- If the specified value is not reached open the lock nut -1-.

Fig 4: Identifying Lock Nut 1
GWWA21-10663Courtesy of AUDI OF AMERICA, LLC

-- Remove the lock washer -3- and remove the actuator rod -2- from the mounting pins.

-- Extend or shorten the front part of the actuator rod by turning left or right.

-- Install the actuator rod -2- on the mounting pins.

-- repeat the test with the Hand Vacuum Pump VAS6213 and the Dial Gauge Set - Dial Gauge VAS6341/1.

-- If the specified value is now reached, install the lock washer and tighten the lock nut.