Home >> Audi >> 2016 >> S4 Premium Plus, Standard Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 555 (Heating, Ventilation & Air Conditioning (1 Of 2) (As Of 06.2014)) >> 87 Air Conditioning >> Refrigerant Circuit >> REAR EXPANSION VALVE WITH Hybrid Battery Refrigerant Shut-Off Valve 2 -N517-, REMOVING AND INSTALLING, Vehicles with 2.0L Hybrid >> Removing

REAR EXPANSION VALVE WITH Hybrid Battery Refrigerant Shut-Off Valve 2 -N517-, REMOVING AND INSTALLING, Vehicles with 2.0L Hybrid: Removing

WARNING: This page does not describe the selected car, but rather 13 other vehicles, including the 2017 Audi SQ5, 2017 Audi Q5, 2016 Audi SQ5, 2016 Audi Q5, and 2015 Audi SQ5. However, it is still accessible from the selected car via links, so may be relevant.

-- Turn off the ignition.

-- Discharge the refrigerant circuit. Refer to USING SERVICE STATION . For additional information, refer to OVERVIEW - REFRIGERANT CIRCUIT, NOT OPENING THE REFRIGERANT CIRCUIT, VEHICLES WITH HIGH VOLTAGE SYSTEM  and OVERVIEW - REFRIGERANT CIRCUIT, OPENING THE REFRIGERANT CIRCUIT, VEHICLES WITH HIGH VOLTAGE SYSTEM  (Refrigerant R134a, Servicing; Refrigerant Circuit, Using Service Station).

-- Remove the luggage compartment floor covering. Refer to LUGGAGE COMPARTMENT FLOOR PANEL, REMOVING AND INSTALLING , also see OVERVIEW - LUGGAGE COMPARTMENT FLOOR .

-- Remove the bolts -2 and 3- and the refrigerant lines -1 and 4-.

Fig 1: Identifying Refrigerant Line Components
GWWA87-11125Courtesy of AUDI OF AMERICA, LLC

-- Disconnect and remove the connector -2- from the bracket.

Fig 2: Identifying Hybrid Battery Refrigerant Shut-Off Valve Components
GWWA87-11139Courtesy of AUDI OF AMERICA, LLC

-- Remove bolts -1-.

-- Remove the Hybrid Battery Refrigerant Shut-Off Valve 2 -N517- -3- from the refrigerant lines to the evaporator.

NOTE:

Close all open lines and connections on the refrigerant line with suitable caps (avoid dirt and moisture from entering the system).