Checking actuation of secondary AIR pump relay
WARNING: This page is about a different car, the 2006 Audi A4, 2005 Audi A4, 2004 Audi A4, and 2003 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.
- Switch off ignition.
- Disconnect secondary AIR pump relay.
- Connect voltage tester VAG1527B as follows:
| 3-way relay carrier in electronics box in plenum chamber, position 2, contact | Measure to |
|---|---|
| 6 | Engine Ground |
- Start output Diagnostic Test Mode and actuate Secondary AIR pump relay J299.
- LED must flash
If LED does not flash:
- Switch off ignition.
- Connect test box VAG1598/31 to engine control module wiring harness. Engine control module must not be connected: → 24 - MULTIPORT FUEL INJECTION (MFI)
- Check for open circuit and short to Ground/positive in following wiring connection:
| 3-way relay carrier in electronics box in plenum chamber, position 2, contact | Test box VAG1598/31 ocket |
|---|---|
| 6 | 66 |
- If necessary, eliminate open circuit/short circuit.
If no fault is found:
- Replace Secondary AIR pump relay J299.