LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S4 Premium Plus, Standard Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 1261 (Turbocharger, Supercharger [CGFA]) >> 21 Turbocharger, Supercharger >> Supercharger >> Supercharger, Checking For Leaks >> Procedure

Supercharger, Checking For Leaks: Procedure

WARNING: This page is about a different car, the 2014 Volkswagen Touareg, 2013 Volkswagen Touareg, 2012 Volkswagen Touareg, and 2011 Volkswagen Touareg. However, it is still accessible from the selected car via links, so may be relevant.

-- Secure the Turbo System Tester Kit - Adapter 13-1:VAG1687/13-1  on the bottom of the supercharger housing.

Fig 1: Attaching V.A.G 1687/13-1 To Bottom Of Supercharger
GWWA21-10457Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

-- Secure the hose connections with hose clamps.

NOTE:

The supercharger is illustrated without the transmission holder.

-- Secure the Turbo System Tester Kit - Adapter 13-3:VAG1687/13-3  on the top of the supercharger housing.

Fig 2: Attaching V.A.G 1687/13-3 To Top Of Supercharger
GWWA21-10459Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

-- Secure the hose connections with hose clamps.

-- Secure the Turbo System Tester Kit - Adapter 13-2:VAG1687/13-2  with Turbo System Tester Kit - Adapter 10:VAG1687/10  to the supercharger housing.

Fig 3: Attaching V.A.G 1687/13-2 And V.A.G 1687/10 To Supercharger
GWWA21-10460Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

-- Secure the hose connections with hose clamps.

Prepare the Turbo System Tester Kit:VAG1687  as follows:

Fig 4: Connecting Pressurized Air Hose To Testing Unit For Turbo Charger V.A.G 1687
GWWV21-0168Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

-- Completely remove the pressure regulating valve -2- and close the valves -3 and 4-.

NOTE:

Pull the knob in order to rotate the pressure regulating valve.

-- Connect the Turbo System Tester Kit:VAG1687  as shown to the compressed air -1- and to the Turbo System Tester Kit - Adapter 10:VAG1687/10  .

Fig 5: Connecting V.A.G 1687 To Compressed Air Using Commercially Available Intermediate Piece -1-
GWWA21-10461Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

-- If there is water in the viewing glass, open the water drain plug -6- and drain the water.

Fig 6: Connecting Pressurized Air Hose To Testing Unit For Turbo Charger V.A.G 1687
GWWV21-0168Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

-- Open the valve -3-.

CAUTION:

Damage could result if the pressure is set too high.

  • The pressure must not exceed 0.5 bar (7.2 psi)!

-- Set the pressure to 0.5 bar (7.2 psi) using the pressure control valve -2-.

-- Open the valve -4- and wait until the test circuit is filled. Regulate the pressure to 0.5 bar (7.2 psi) again if necessary.

-- Close the valve -3- and observe the pressure gauge.

-- Inspect the charge air system for poorly sealed areas by listening, feeling, using commercially available leak detection spray or by using the Ultrasonic Tester:VAG1842S  .

NOTE:

Refer to the Owner's Manual for information on using the Ultrasonic Tester:VAG1842S  .

Release the pressure in the test circuit by pulling off the hose coupling before removing the adapter.