Camshaft, Measuring Axial Clearance: Procedure
WARNING: This page is about a different car, the 2010 Audi A5, 2009 Audi A5, and 2008 Audi A5. However, it is still accessible from the selected car via links, so may be relevant.
-- Remove the camshafts. Refer to CAMSHAFT, REMOVING AND INSTALLING .
-- Mark the allocation of the roller rocker lever and the hydraulic adjusting elements so they can be installed again.
-- If necessary, remove the roller rocker levers with the hydraulic adjusting elements and place them on a clean surface.
-- Secure the Dial Gauge Holder:VW387 with the Dial Gauge - 0-10mm:VAS6079 on the cylinder head ash shown in the illustration.
-- Determine the axial play.
- Axial play: 0.100 to 0.191 mm.