LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S4 Premium Plus, Standard Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 1138 (Maintenance, Diagnosis (Maintenance Procedures) (Coupe)) >> 03 Maintenance, Diagnosis >> Maintenance Procedures >> Cooling System, Checking Freeze Protection And Filling >> Coolant Level, Checking And Filling

Coolant Level, Checking And Filling

WARNING: This page does not describe the selected car, but rather 23 other vehicles, including the 2017 Audi S5, 2017 Audi A5 Quattro, 2016 Audi S5, 2016 Audi A5 Quattro, and 2015 Audi S5. However, it is still accessible from the selected car via links, so may be relevant.

Special Tools And Workshop Equipment Required 

The refractometer scale -1- is designed for coolant additives G11, G12, G12 Plus and G12 Plus Plus.

Fig 2: Identifying Scales On Refractometer: Coolant Additive G12 Plus -1- And Coolant Additive G13 -2-
GWWN01-11032Courtesy of AUDI OF AMERICA, LLC

The scale -2- is designed only for coolant additive -G 13-.

WARNING:

The Coolant Reservoir Is Under Pressure. Open It Only When The Engine Is Cold.

CAUTION:

Use Only Distilled Water For Mixing Coolant Additives. Optimum Corrosion Protection Can Be Reached Only By Using Distilled Water.

NOTE:

The Vehicle Must Level.

Approved frost protection additives: refer to the appropriate service information.

The water used for mixing greatly influences the effectiveness of the coolant. In order to have a coolant mixture for all countries, always use distilled water to mix the coolant in older models.

G12 ++ and G13 can also be mixed with coolant additives G11, G12 and G12+.

-- Check the coolant level in the reservoir when the engine is cold.

-- If coolant level is too low: fill with coolant mixture.

NOTE:

Small Quantities Of Coolant Can Be Refilled When Larger Quantities Of Coolant Are Needed When Filling, Cooling System Filling Equipment :VAS 6096  should be used.

Consult the Operating Instructions that come with the coolant system filler unit:VAS 6096  .

Determine cause of fluid loss which cannot be attributed to normal use and rectify (repair measure).

Freeze protection to Coolant additive Water
-13°F (-25°C) approximately 40 % approximately 60 %
-33°F (-36 °C) approximately 50 % approximately 50 %