LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> A6 Premium >> Repair and Diagnosis >> External Pages >> Different car >> Section 194 (Blind Spot Monitor System (Diagnostic Codes & Circuit Tests)) >> Blind Spot Monitor System >> Circuit Tests >> Power Source Circuit [08/2013 - ] >> Procedure

Power Source Circuit [08/2013 - ]: Procedure

WARNING: This page is about a different car, the 2014 Lexus ES 300h. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR LH - AUXILIARY BATTERY) 
    1. Disconnect the U8 blind spot monitor sensor LH connector.
    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage

      Tester Connection Condition Specified Condition
      U8-5 (BLB) - Body ground Power switch on (IG) 11 to 14 V
      U8-5 (BLB) - Body ground Power switch off Below 1 V

    NG → REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: Go to next step 

  2. CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR LH - BODY GROUND) 
    1. Disconnect the U8 blind spot monitor sensor LH connector.
    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      U8-10 (BLGD) - Body ground Always Below 1 Ω

    NG → REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: Go to next step 

  3. CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR RH - AUXILIARY BATTERY) 
    1. Disconnect the U9 blind spot monitor sensor RH connector.
    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage

      Tester Connection Condition Specified Condition
      U9-5 (BRB) - Body ground Power switch on (IG) 11 to 14 V
      U9-5 (BRB) - Body ground Power switch off Below 1 V

    NG → REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: Go to next step 

  4. CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR RH - BODY GROUND) 
    1. Disconnect the U9 blind spot monitor sensor RH connector.
    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      U9-10 (BRGD) - Body ground Always Below 1 Ω

    NG → REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK → See step   5 

  5. PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to  PROBLEM SYMPTOMS TABLE [08/2013 - ]