LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> A3 TDI Prestige >> Repair and Diagnosis >> Engine Mechanical >> Exhaust >> EXHAUST SYSTEM (4-Cylinder TDI Common Rail 1.6L; 2.0L 4V Engine) -- (A3 SEDAN) >> 26 Exhaust System >> Selective Catalytic Reduction System >> Reducing Agent Line Connector, Disconnecting

Reducing Agent Line Connector, Disconnecting

Special Tools And Workshop Equipment Required 

CAUTION:

There is a risk of injury due to escaping reducing agent.

Reducing agents may cause eye and skin irritation as well as injury to the respiratory system and possible poisoning.

- Wear protective eyewear.

- Wear safety gloves.

- Wear protective work clothing.

- Make sure there is a fresh air supply. Turn on exhaust extraction when in closed spaces.

-- Drain the reducing agent.

Use the Vehicle Diagnostic Tester.

-- Clean the area around the clamp with water.

-- To catch escaping reducing agent place a clean cloth under the coupling point.

-- Push the connector opposite the direction of -arrow 2-.

-- Push the reducing agent clip -1- together as shown in the direction of the -arrow 1-.

GWWN26-10470Courtesy of AUDI OF AMERICA, LLC

-- Remove the reducing agent line in the direction of -arrow 2- without special equipment and without sharply pulling on it.

-- To catch escaping reducing agent place a clean cloth under the separation point.

-- Seal all the open lines and connections with clean plugs from the :VAS6122  .